ME31-XDXX0400 4-way temperature acquisition module PT100 thermal resistor RS485 network port to Modbus K-type thermocouple [Communication interface]:RJ45, RS485 [Working voltage]:DC 8~28V [Installation method]:Guide rail/screw [Introduction]:ME31-XDXX0400 is a PT100 thermal resistor temperature... Read more

Availability: In Stock

Free Gift: TI Samples $0.00, ESP32 Samples $0.00(Black Friday Only)

Shipping: Free Air Shipping Over $79.99

Ship From: China EBYTE Manufacturer Factory

Bulk Purchase Tips: Please confirm the firmware version of the test sample with the salesperson before purchasing

Order today. Get it and , hoursminutes
Produit en rupture
Référence produit : ME31-XDXX0400N/ATags : IO, New product, RJ45, RS485

Guaranteed Safe Checkout

paypalvisadiscovermaestroamerican express

Every day, EBYTEIOT serves hundreds of clients worldwide, ensuring that we always remain responsive.

Free Shipping: All product orders with a total amount exceeding $79.99 qualify for free shipping.

Total time = processing time + shipping time (shipping time is business days)

Processing time = the time between placing an order and us shipping it.

Shipping time = the time it takes for your order to be shipped and delivered to you.

Processing time: 7 working days


Shipping time: 7-15 working days by China Post Air Mail (may take up to 45 working days due to unpredictable factors such as weather and customs processing).

 

Please be advised that we do not deliver to

  • Cuba
  • Islamic Republic of Iran
  • Democratic People's Republic of Korea (North Korea).
  • Sudan
  • Syria
  • Venezuela
  • Yemen

We apologize for any inconvenience this may cause.

 

Cancel order

We accept order cancellations before the product is shipped. If your order is canceled, you will receive a full refund. We cannot intercept order cancellations if the product has already been shipped.


Returns

We accept product returns. Customers have the right to request a return within 30 days of receipt of the product. To be eligible for a return, your item must be unused and in the same condition you received it. It must also be in its original packaging. To complete your return, we require a receipt or proof of purchase.

If the return is caused by the consumer, the consumer will bear the shipping costs. The exact cost depends on the courier company you choose.

If the product is damaged or unusable due to our fault, such as product or transportation reasons, please contact EBYTE: ebyteiot@cdebyte.com. After communication with our technical staff, we will arrange for a reissue or refund.


Refund

Once your return has been received and inspected, we will send you a delivery notification via email. We will also notify you of approval or rejection of the refund. If you're approved, your refund will be processed and automatically credited to your credit card or original payment method within 15 business days.

Contact

Contact our customer service at ebyteiot@cdebyte.com.

Tel: +086 028 61543675

Return address: Building B5, No. 199, West District Avenue, High Tech West District Chengdu, China.

 

EBYTE product technical manual and detailed parameters download: https://www.cdebyte.com/Product-Selection

ME31-XDXX0400 4-way temperature acquisition module PT100 thermal resistor RS485 network port to Modbus K-type thermocouple

[Communication interface]:RJ45, RS485

[Working voltage]:DC 8~28V

[Installation method]:Guide rail/screw

[Introduction]:ME31-XDXX0400 is a PT100 thermal resistor temperature acquisition module with 4-channel PT100 temperature acquisition function, and supports the acquisition of 2/3-wire PT100 temperature sensors. It also has a display screen to facilitate customers to debug and configure on-site and view the temperature. This temperature acquisition module supports both network and RS485 communication interfaces, and supports Modbus TCP protocol or Modbus RTU protocol for acquisition. It can also be used as a Modbus gateway, automatically sending instructions from non-local Modbus addresses through the serial port/network port, supporting Modbus TCP and Modbus RTU protocol conversion, and convenient for expanding Modbus slave .

Category  Name  Parameters
power supply Working voltage DC8~28V
Power indicator Blue LED indication
Communication Communication interface RJ45, RS485
Baud rate 1200~115200bps (default 9600)
Communication protocol Standard Modbus TCP, Modbus RTU protocol
MODBUS Device address Can be modified through Modbus command, host computer, device button
Temperature collection Number of channels 4-way
Sensor type 2, 3-wire PT100 temperature sensor
Temperature resolution 0.1℃
Accuracy Normal temperature (25±5℃) condition: ±0.1%±1℃
Full temperature (-40~85℃) condition: ±0.5%±1℃
Collection frequency 1Hz
Collection display OLED screen display
other Product size 121mm * 72mm * 34mm (length * width * height)
Product weight 140 ±5 g
Working temperature and humidity -40 ~ +85℃, 5% ~ 95%RH (no condensation)
Installation method Guide rail installation, screw installation


Category  Name  Parameters
Ethernet parameters Working mode TCP server (up to 4 client accesses)
Local IP 192.168.3.7
Local port 502
Subnet mask 255.255.255.0
Gateway address 192.168.3.1
DHCP Off
Local MAC Determined by the chip (fixed)
Target IP 192.168.3.3
Target port 502
DNS server 114.114.114.114
Active upload Off
Serial port parameters Baud rate 9600bps (8 types)
Check method None
Data bit 8
Stop bit 1
MODBUS Parameters Modbus master-slave Slave
Address 1

High precision and stability
Parameter Comparison Table
16 core functions
High-precision acquisition
High protection isolation
Real-time temperature display

Key Configuration

RS485 Cascade Expansion

Support 4-way socket link

ModBus Gateway Features


Dimanche, Lundi, Mardi, Mercredi, Jeudi, Vendredi, Samedi
Janvier,Février,Mars,Avril,Mai,Juin,Juillet,Août,Septembre,Octobre,Novembre,Décembre
Articles en stock insuffisant. Plus que [max] en stock.
Ajouter à la liste d'enviesParcourir la liste d'enviesSupprimer la liste d'envies
Panier d'achat

Votre panier est vide.

Return To Shop

Ajouter un message à votre commandeEditer la note de votre commande
Calculer les frais de port
Ajouter un code de réduction

Calculer les frais de port

Ajouter un code de réduction

Le code de réduction fonctionnera au moment du paiement

EBYTE ME31-XDXX0400 Temperature Acquisition Module 4-way PT100 RTD Ethernet RS485 With OLED Display Screen Support Modbus

$34.99