Ebyte JGD111 EtherCAT Remote IO Module 16DI+16DO / 8DO DC 9-36V DIN Rail – Ebyte Official Store - IoT Module Manufacturer

Ebyte JGD111 EtherCAT Remote IO Module 16DI 16DO DIN Rail EtherCAT IN/OUT

$68.24

Shipping calculated at checkout.

The Ebyte JGD111-EDMP1616 and JGD111-EDR08 are book-style EtherCAT remote I/O modules that give a PLC, motion controller or industrial PC real-time access to field I/O over standard EtherCAT, with two RJ45... Read more

Three Protections: The shell adopts three-proof coating, which is Anti-Fungal, Anti-Humidity, and Anti-Salt Spray.

Shipping: Free Air Shipping Over $89.99(China Post only)If the China post cannot deliver, other logistics need to pay extra postage delivery

Ship From: China EBYTE Manufacturer Factory

Bulk Purchase Tips: Please confirm the firmware version of the test sample with the salesperson before purchasing

Order today. Get it and , hoursminutes

SKU: JGD111-EDMP1616 (16DI + 16DO EtherCAT Remote IO, DC 9~36V, DIN Rail)

  • JGD111-EDMP1616 (16DI + 16DO EtherCAT Remote IO, DC 9~36V, DIN Rail)
  • JGD111-EDR08 (8DO EtherCAT Remote IO, DC 9~36V, DIN Rail)
Ne sera pas expédié avant [19041994]
$68.24
Produit en rupture

Guaranteed Safe Checkout

paypalvisadiscovermaestroamerican express

Ebyteiot provides invoices. Bulk order discounts. 24/7 tech support, Manuals and certifications available. Product Selection Guide Download: IoT Module&Modem Selection Guide.pdf

Every day, EBYTEIOT serves hundreds of clients worldwide, ensuring that we always remain responsive.

1、Free Shipping Terms

1.1、Free shipping only for wireless modules on orders over $89.99.

1.2、Orders containing Modem, fiberglass antennas, magnetic base antennas or power supply modules are not eligible for free shipping (overweight, magnetic or battery-equipped goods).

1.3、Due to the temporary inability of postal channels to ship to Europe and the United States, goods to Europe and the United States will be delivered via Yanwen Express Line. Please be aware that additional shipping costs may apply to orders to more remote areas.

1.4、We offer shipping insurance in partnership with xcottonsp for all orders.
Simply select the shipping insurance option at checkout. Should your order be undeliverable or lost in transit, you will be reimbursed for the full order value. For more information, please visit:
For consumers wishing to file a claim regarding Shipping Protection, Consumers wishing to file a claim regarding shipping protection may contact Xcotton via any of the following methods:
1. Click the "File a claim" option within the confirmation email received after purchase (subject line: "Xcotton Shipping Protection Placed Successfully").
2. Visit this link to file a claim: https://sp.xcottons.com/parcel#/parcel/parcel-login
3. Contact us via email at:  support@xcottons.com.
4. Claims FAQ:https://sp.xcottons.com/#/more/SPDL5
5. Xcotton Terms and Conditions of Use:https://www.xcottons.com/#/terms/SP-delay

2、Total time

Total time = processing time + shipping time (shipping time is business days)

Processing time = the time between placing an order and us shipping it.

Shipping time = the time it takes for your order to be shipped and delivered to you.

Processing time: 7 working days

Shipping time: 7-30 working days by China Post Air Mail.

We offer express delivery via DHL, FedEx, UPS and more. Extra shipping fees apply: https://ebyteiot.com/products/ebyte-dedicated-link-for-paying-postage

Important Reminder: (Shipment may take several months at maximum due to uncontrollable factors including wars, geological disasters, bad weather and customs clearance.)

3、Customs Duties and Taxes (DDU/DAP)

EBYTEIOT shall not be responsible for any customs duties or taxes incurred by your order. All charges arising during or after shipment (including customs duties, taxes, etc.) shall be borne by the customer.

4、Shipment Confirmation & Order Tracking

Once your order has been shipped, you will receive a shipment‑confirmation email containing your tracking number. The tracking number will become active within 24‑48 hours.
Track your shipment at:  https://www.17track.net/en

5、Damaged & Lost Packages

If you receive a damaged order or your package is lost in transit, please contact us immediately via ebyteiot@cdebyte.com, and provide your order number together with photos of the damaged items.

6、Please be advised that we do not deliver to

  • Cuba
  • Islamic Republic of Iran
  • Democratic People's Republic of Korea (North Korea).
  • Sudan
  • Syria
  • Venezuela
  • Yemen
  • Colombia
  • Israel

We apologize for any inconvenience this may cause.


Cancel order

We accept order cancellations before the product ships. If your order is cancelled, you will receive a full refund. If the product has already been shipped, the buyer can initiate a return or refund request within 30 calendar days of receiving the goods.


Returns

We accept product returns. Customers have the right to request a return within 30 days of receipt of the product. To be eligible for a return, your item must be unused and in the same condition you received it. It must also be in its original packaging. To complete your return, we require a receipt or proof of purchase.

If the return is caused by the consumer, the consumer will bear the shipping costs. The exact cost depends on the courier company you choose.

If the product is damaged or unusable due to our fault, such as product or transportation reasons, please contact EBYTE: ebyteiot@cdebyte.com. After communication with our technical staff, we will arrange for a reissue or refund.


Refund

Once your return has been received and inspected, we will send you a delivery notification via email. We will also notify you of approval or rejection of the refund. If you're approved, your refund will be processed and automatically credited to your credit card or original payment method within 15 business days.


Contact

Contact our customer service at ebyteiot@cdebyte.com.

Tel: +086 028 61543675

Return address: Building B5, No. 199, West District Avenue, High Tech West District Chengdu, China.

 

Auto-download documents via Ebyte official website link:

The Ebyte JGD111-EDMP1616 and JGD111-EDR08 are book-style EtherCAT remote I/O modules that give a PLC, motion controller or industrial PC real-time access to field I/O over standard EtherCAT, with two RJ45 ports for EtherCAT IN and OUT daisy-chain cabling, a 1 ms internal bus, 16 DI plus 16 DO on the EDMP1616 or 8 DO on the EDR08, DC 9~36V supply with reverse-polarity protection and 2~4W consumption, per-channel optocoupler isolation on inputs of DC 12~28V with 7.2kohm input impedance and 1000 Hz sampling, EMC level-3 protection design and CE compliance in a 120x30x80mm DIN-rail housing.

Key Features & Advantages

  • Real-Time EtherCAT I/O Extension: These modules speak the standard EtherCAT protocol, so process data is exchanged on the fly as the frame traverses the module, and the internal bus runs up to 1 ms. That is the functional difference from a Modbus TCP remote I/O block: with EtherCAT the controller sees deterministic image data instead of a polled register read, which is what a coordinated axis or a fast interlock needs.
  • Dual RJ45 EtherCAT IN and OUT For True Daisy-Chaining: Two Ethernet ports let the module sit inline on the drop cable and pass the next segment downstream without a switch or a spare controller port. In a multi-station machine this removes one active network device per node and shortens the cable tree, which is also where most of the EMC exposure lives.
  • Per-Channel Isolated Inputs With Fast Capture: The DI side accepts DC 12~28V from either NPN or PNP sensors, isolates every channel individually with an optocoupler, presents a 7.2kohm input impedance, and samples at 1000 Hz. Per-channel isolation matters in practice: it stops one miswired or shorted sensor from corrupting the whole input group, and 1000 Hz is fast enough to catch a 50 ms pulse that a slower scanner silently drops.
  • EMC Level-3 Protection Design: The series is built to an EMC level-3 protection design with full isolation between the I/O side and the power side, which is the specification that decides whether the module survives next to contactors, VFDs and servo drives instead of randomly tripping or reading ghost inputs.
  • DC 9~36V Input With Reverse-Polarity Protection: The 9~36V window covers 12V and 24V control rails with headroom, consumption is 2~4W, a red PWR LED confirms the internal rail, and the input is protected against reverse polarity — a real saving on a site where the field wiring is done by hand under time pressure.
  • Book-Style 30mm Housing With Two Mounting Options: The 120x30x80mm form factor fits a standard 35mm DIN rail and also offers locating-hole mounting, so the same part can be rail-mounted in a cabinet or screw-fixed where vibration makes rail-only retention questionable.

Core Specifications

Compiled from the JGD111 official per-model parameter table and the JGD111 series comparison table. Cells marked [to be confirmed] are not published on the product pages and must be read from the JGD111-EDMP1616 / JGD111-EDR08 user manual (linked as the technical manual download) before design freeze.

Category Item JGD111-EDMP1616 JGD111-EDR08
Product Type Book-style remote I/O module Book-style remote I/O module
I/O configuration Channels 16 DI + 16 DO 8 DO
Communication Protocol Standard EtherCAT Standard EtherCAT
Communication Ports Dual Ethernet, EtherCAT IN / OUT Dual Ethernet, EtherCAT IN / OUT
Communication Internal bus Up to 1 ms Up to 1 ms
DI input Sensor type accepted NPN and PNP Not applicable - no DI channels
DI input Input range / impedance DC 12~28V, 7.2kohm Not applicable
DI input Isolation / sampling Per-channel optocoupler isolation, 1000 Hz Not applicable
DI input Counting frequency 1 kHz (1000 Hz sampling filter) Not applicable
DO output Output type / rating 16-channel transistor output (PNP/NPN)
• Maximum current per channel: 0.5 A
• Rated voltage: 24 V DC
8-channel relay output
• Contact capacity: AC 250V / 5A
• Rated DC: DC 30V / 5A
Power Working voltage DC 9~36V with reverse-polarity protection DC 9~36V with reverse-polarity protection
Power Consumption / indicator 2~4W, red PWR LED 2~4W, red PWR LED
Protection Design EMC level-3 protection, I/O-to-power full isolation EMC level-3 protection, I/O-to-power full isolation
Certification Stated compliance CE (as stated on the product page) CE (as stated on the product page)
Mechanical Dimensions / mounting 120 x 30 x 80 mm; locating holes and DIN rail 120 x 30 x 80 mm; locating holes and DIN rail
Mechanical Weight 140 +/- 5 g 160 +/- 5 g
Environment Operating temperature -40 °C to +85 °C -40 °C to +85 °C
Integration Master side PLC, motion controller, industrial PC acting as EtherCAT master PLC, motion controller, industrial PC acting as EtherCAT master

Product Selection Guide

Notice for Selection: These are wired EtherCAT I/O nodes, not radio devices - there is no ISM band or antenna question here, but there are two hard checks. First, confirm your controller is genuinely an EtherCAT master (Beckhoff TwinCAT and TwinCAT-compatible masters, or an EtherCAT-capable PLC); a Siemens PROFINET or Modbus TCP controller cannot use this family, and the same 120x30x80mm book-style housing is sold as JGD111-PDMP1616 / JGD111-PDR08 for PROFINET RT and JGD111-MDMP1616 / JGD111-MDR08 for Modbus TCP, so buy the protocol variant that matches the controller, not the I/O count. Second, confirm the DO output type and rated current from the manual before committing to a load, since the product page states the channel count but not the output rating.

Your situation Recommended model Why
Machine needs both sensor inputs and outputs on one EtherCAT node JGD111-EDMP1616 16 DI + 16 DO in one 30mm book housing, isolated NPN/PNP inputs at 1000 Hz
Only output actuation is needed where inputs are already collected elsewhere JGD111-EDR08 8 DO, lower cost point, same EtherCAT IN/OUT daisy-chain and EMC design
Controller is PROFINET (Siemens family) JGD111-PDMP1616 / JGD111-PDR08 Same housing and I/O classes on PROFINET RT - listed for cross-checking only
Controller speaks Modbus TCP and polling is acceptable JGD111-MDMP1616 / JGD111-MDR08 Same housing on Modbus TCP with standard register access
Need many nodes along one drop cable Either EtherCAT model Dual RJ45 IN/OUT lets each module pass the bus onward without a switch

Ebyte JGD111 EtherCAT Remote IO Module Detail 102

Ebyte JGD111 EtherCAT Remote IO Module Detail 103

Ebyte JGD111 EtherCAT Remote IO Module Detail 104

Ebyte JGD111 EtherCAT Remote IO Module Detail 106

Ebyte JGD111 EtherCAT Remote IO Module Detail 107

Ebyte JGD111 EtherCAT Remote IO Module Detail 109

Ebyte JGD111 EtherCAT Remote IO Module Detail 110

Ebyte JGD111 EtherCAT Remote IO Module Detail 111

Ebyte JGD111 EtherCAT Remote IO Module Detail 112

Ebyte JGD111 EtherCAT Remote IO Module Detail 201

Ebyte JGD111 EtherCAT Remote IO Module Detail 202

Ebyte JGD111 EtherCAT Remote IO Module Detail 203

Ebyte JGD111 EtherCAT Remote IO Module Detail 204

Ebyte JGD111 EtherCAT Remote IO Module Detail 205

Ebyte JGD111 EtherCAT Remote IO Module Detail 206

Ebyte JGD111 EtherCAT Remote IO Module Detail 207

Industrial Installation & Wiring

1. Mounting: Clip onto a 35mm DIN rail or screw-fix through the locating holes. The 30mm width is what allows dense rows, but keep vertical clearance above the terminals for the cable ferrules and leave a neighbour-free gap next to any heat-dissipating device, because the terminal block is where the temperature actually accumulates.

2. Power: Supply DC 9~36V to the power terminals. The input is reverse-polarity protected and the module draws 2~4W, so a 24V rail shared across a row of nodes should be sized for the aggregate, and each branch should still be fused. The red PWR LED is your first diagnostic - no lamp means check the fuse and the terminal screw before touching the configuration.

3. EtherCAT topology: EtherCAT IN receives the frame from the master or the previous node; EtherCAT OUT feeds the next node. This is a linear drop-cable topology by design, so do not star-wire the ports through a hub or switch, and terminate the last node by leaving OUT unconnected as the master expects. Cable length per segment must respect the EtherCAT physical-layer limits for your baud and cable class.

4. Sensor wiring (EDMP1616): The inputs accept NPN or PNP sensors over DC 12~28V with 7.2kohm input impedance, and each channel is individually optocoupler isolated. Respect the common/group arrangement shown in the pin-definition table of the manual: an isolated input still needs its reference wired to the correct common, otherwise a floating common produces ghost triggers that look like a module fault.

5. Load wiring: Confirm the DO output type and rated current in the manual before connecting contactors, valves or lamps, and keep inductive loads protected at the coil (free-wheeling diode for DC coils, RC snubber for AC). The isolation between the I/O side and the power side protects the bus and the controller, not the output device - external protection is still your responsibility.

6. EMC practice: The series uses an EMC level-3 protection design with I/O-to-power isolation, but the installation still has to cooperate: bond cable screens at the cabinet entry, keep signal and power cables in separate trunking, and route the EtherCAT cable away from servo and VFD power runs. Isolation ratings buy you immunity margin, not immunity from bad wiring practice.

7. Commissioning: Import the module description into your EtherCAT master so the process-data image matches what the firmware exposes, then verify by forcing outputs and monitoring the input image while cycling sensors. The 1 ms internal bus means an input change should appear in the master image essentially immediately - if it does not, suspect the common wiring before suspecting the module.

Practical Application Scenarios

1. Distributed I/O On Packaging And Assembly Machines

A packaging line needs cylinder sensors, part-presence probes and valve outputs spread over several metres of frame. Running one EtherCAT drop cable between EDMP1616 nodes replaces a bundle of individual cables back to the control cabinet, and the 1 ms internal bus plus on-the-fly processing keeps the I/O coherent with the motion group instead of drifting a cycle behind it.

2. Safety-Adjacent Interlocks And Machine Guarding Signals

Guard switches, light-curtain muting signals and home-position probes are exactly the signals that must not be missed. 1000 Hz sampling catches short pulses, per-channel isolation stops one damaged sensor from poisoning its neighbours, and the EMC level-3 design is what keeps ghost inputs from appearing next to the drives on the same machine frame. (Note the manufacturer statement: this product must not be used in military or life-safety applications.)

3. Output-Only Actuation Panels Near The Process

Where inputs are already handled by an existing block but valves, lamps, relays and buzzers sit far away, the 8-DO JGD111-EDR08 gives a local actuation point on the same EtherCAT segment at a lower cost per node, and its dual ports let the bus continue to the next panel without an extra switch.

4. Test Benches And Data Acquisition Rigs

A test rig changes its I/O map between programs far more often than a production machine does. EtherCAT process data with a deterministic bus cycle gives repeatable timing for correlation between stimulus and capture, and one 16 DI + 16 DO node covers most bench needs without bespoke conditioning hardware.

FAQ Section

Q1: What is the actual difference between the two EtherCAT models, beyond the channel count?

Electrically and mechanically they are the same node family: identical 120x30x80mm book housing, DC 9~36V supply with reverse-polarity protection, 2~4W consumption, dual EtherCAT IN/OUT ports, 1 ms internal bus, EMC level-3 design and CE statement. The difference is the I/O stage: JGD111-EDMP1616 provides 16 DI plus 16 DO, so it can sense and actuate from one position, while JGD111-EDR08 provides 8 DO only and carries no input channels - the input specifications in the shared parameter table therefore do not apply to it. Choose EDMP1616 when sensors terminate locally; choose EDR08 when you only need outputs closer to the process.

Q2: My controller already has a Modbus TCP remote I/O node - is EtherCAT worth switching to?

Only if you actually need what EtherCAT changes. Modbus TCP is polled: each value costs a request and a response, and the update rate depends on slave response time and how many registers you read. EtherCAT moves data as the frame passes each node, so the whole image refreshes together at the master cycle - up to 1 ms internal bus here - and that coherent-snapshot behaviour is what matters for motion coordination, fast interlocks and timestamped capture. If your machine is content with tens of milliseconds of polling latency, the Modbus TCP variants in the same housing are the cheaper path.

Q3: Why does the DI side need 12~28V when the module itself runs on 9~36V?

They are two different circuits. The 9~36V rail powers the logic, the Ethernet PHY and the isolation barriers; the 12~28V figure is the sensor-signal range the input stage is designed to read through its 7.2kohm impedance and optocoupler. That is why a 24V sensor works directly, and why an 8V signal from a low-voltage proximity switch is not guaranteed to be read reliably even though the module itself is powered fine - drive the input with the specified signal voltage, not with the supply rail assumption.

Q4: The module has per-channel isolation - does that mean I can ignore common wiring?

No. Per-channel optocoupler isolation separates each input electrically from the internal logic and from the power domain, which protects the module and prevents one shorted sensor from dragging its neighbours down. It does not remove the need for a correct reference: the input groups still need their commons wired as the pin-definition table specifies, and the cable screen and PE bonding still determine how much conducted noise reaches the terminal. Most field faults reported as module failure are wiring-reference problems, and the manufacturer explicitly excludes military and life-safety use, so this is not a component to work around.

SKU

JGD111-EDMP1616 (16DI + 16DO EtherCAT Remote IO, DC 9~36V, DIN Rail), JGD111-EDR08 (8DO EtherCAT Remote IO, DC 9~36V, DIN Rail)

Disclaimer:This product is strictly prohibited for use in military applications and scenarios related to life safety. The user shall be fully liable for any unauthorized use.

Dimanche, Lundi, Mardi, Mercredi, Jeudi, Vendredi, Samedi
Janvier,Février,Mars,Avril,Mai,Juin,Juillet,Août,Septembre,Octobre,Novembre,Décembre
Articles en stock insuffisant. Plus que [max] en stock.
Ajouter à la liste d'enviesParcourir la liste d'enviesSupprimer la liste d'envies
Panier d'achat

Votre panier est vide.

Return To Shop

Ajouter un message à votre commandeEditer la note de votre commande
Calculer les frais de port
Ajouter un code de réduction

Calculer les frais de port

Ajouter un code de réduction

Le code de réduction fonctionnera au moment du paiement

Ebyte JGD111 EtherCAT Remote IO Module 16DI 16DO DIN Rail EtherCAT IN/OUT

JGD111-EDMP1616 (16DI + 16DO EtherCAT Remote IO, DC 9~36V, DIN Rail)
JGD111-EDMP1616 (16DI + 16DO EtherCAT Remote IO, DC 9~36V, DIN Rail)
$68.24