[Specifications]:4DI + 2DO
[Interface mode]:RS485
[Installation method]:positioning hole
[Product weight]:80±5g
[Size]:50*80mm
Manual Download
manual
configuration tool
Company Proflile
| parameter name | value |
|
Operating Voltage |
8~28V (DC) |
| Communication interface | RS232/RS485 |
| Protocol | Modbus RTU |
| baud rate | 1200~115200 bps(default 9600 bps) |
| data bit | 8 |
| stop bit | 1 |
| Check Digit | None |
| Digital input (DI) | stem node |
| Analog input (AI) | - |
| Acquisition frequency | 100 Hz |
| trigger method | Pulse trigger / level trigger |
| Digital output (DO) | Relay output |
| Contact capacity (DO) | 10A/30 VDC 、 10A/250 VAC |
| Power indicator (Power) | Green LED indication |
| Input indication (DI) | Green LED indication |
| Input Indication (AI) | Green LED indication |
| Output indication (DO) | Red LED indication |
| Working temperature, humidity | -40℃ ~ +85℃ 、5%~95%RH 、no condensation |
| storage temperature, humidity | -60℃ ~ +125℃ 、5%~95%RH 、no condensation |
| installation method | Rail installation or positioning hole installation |


Practical Application Scenarios
1. Production Line Equipment Status Monitoring with NB144 Serial Server
Connect MA01-AXCX4020 DI ports to proximity switches and emergency stop buttons on automated assembly lines, upload equipment running signals via RS485 bus to Ebyte NB144 4-channel serial server. The module’s 100Hz fast sampling captures transient fault signals instantly, relay DO channels control line alarm lights and solenoid valves for interlock protection. Optoelectronic isolation eliminates motor EMI interference in high-power production workshops, and Modbus RTU data is forwarded to remote factory SCADA platforms over Ethernet.2. Smart Greenhouse Irrigation Automatic Control System
Match this remote IO module with Ebyte EID041 temperature humidity transmitters; DI channels read soil moisture dry contact sensor signals, DO ports drive water pump and ventilation fan contactors. Wide DC8-28V voltage adapts off-grid solar power supply for field greenhouses, dual rail & wall mounting fits compact control boxes, and anti-surge hardware protects circuits from outdoor lightning surge interference.3. Building Access Control & Exhaust Fan Linkage Management
Deploy MA01-AXCX4020 inside weak current cabinets of office buildings: DI collects door magnetic switch and card reader trigger signals, DO automatically starts workshop exhaust fans when access control is activated. Dry contact DI design matches mainstream access control hardware, standard Modbus protocol connects to building PLC, and industrial wide temperature range works stably in unheated basement equipment rooms.4. Photovoltaic Junction Box Fault Signal Collection
Install multiple MA01-AXCX4020 units at distributed PV combiner boxes, DI channels collect circuit breaker on-off status signals of each string, relay DO outputs trigger site warning beepers for abnormal power generation. RS485 bus long-distance transmission reduces wiring costs across large solar farms, three-proof shell coating resists dust and salt fog in open-air photovoltaic stations.5. Warehouse Conveyor Safety Interlock Control
Link DI ports to safety grating and limit position sensors on logistics conveyor belts, DO channels control conveyor motor contactors to cut power when safety signals trigger. Pulse trigger mode captures fast belt movement signals without data loss, EMC multi-layer protection avoids signal distortion from frequency converter electromagnetic noise, and compact size saves cabinet installation space.