E91-DTU LoRa RS485 Wireless Modem 30-37dBm IP67 Modbus – Ebyte Official Store - IoT Module Manufacturer

E91-DTU LoRa RS485 Wireless Modem 30-37dBm IP67 Modbus

$27.30

Стоимость доставки рассчитывается при оформлении.

E91-DTU series is an industrial-grade LoRa RS485 wireless data transmitter featuring up to 37dBm output, IP67 waterproof protection, and Modbus protocol support for high-reliability, long-range communication in harsh environments. Parameter Specifications... Read more

Availability: In Stock

Shipping: Free Air Shipping Over $89.99(China Post only)If the China post cannot deliver, other logistics need to pay extra postage delivery

Ship From: China EBYTE Manufacturer Factory

Bulk Purchase Tips: Please confirm the firmware version of the test sample with the salesperson before purchasing

Order today. Get it and , hoursminutes

Specifications: E91-DTU(400SL30)

  • E91-DTU(400SL30)
  • E91-DTU(400SL37)
  • E91-DTU(900SL30)
Не будет отправлено до [19041994]
$27.30
Распродано
Артикул: E91-DTU(400SL30)Н/ДТеги: 30dBm, 37dBm, DTU, RS485

Guaranteed Safe Checkout

paypalvisadiscovermaestroamerican express

When will the order be shipped?

We have sufficient goods in stock. We will send out goods within 1 to 2 working days after payment. We use China Post Air Mail as our regular shipping method. It normally takes 7 to 15 working days to arrive. Free shipping applies to orders over $89.99, excluding fiberglass antennas and power supplies. More Shipping Policies

How can I track my shipment?

After shipment, you will receive an email with the tracking number, such as LZ4177733XXCN. Check logistics status here: https://ebyteiot.com/apps/17TRACK

How to buy samples priced at $0.1?

You can mix different sample types. Each order can buy maximum 2 pieces. Buy $0.1 Sample

Where can I download product manuals?

You can download related documents directly on each product page. More materials:https://www.cdebyte.com/Product-Selection

How about product performance?

All EBYTE products support return and exchange within 30 days. Our items work steadily and you do not need to worry about after-sales problems.

What certifications do the products own?

Our goods have passed CE, FCC and RoHS certifications. You can download certification files on product pages directly, fully meeting compliance requirements.

What is the price for bulk purchase?

You can place bulk orders directly online. Large orders of 50, 200, 500, 1000 pieces and above enjoy factory discounted prices. Shipping cost can be checked on the page. Delivery takes 7 to 15 working days.

Why check firmware version before bulk order?

If you buy products in large quantity, please confirm the firmware version of bulk goods is the same as your test sample. This ensures normal operation of your project.
If you cannot confirm the version number, contact online customer service or send emails to ebyteiot@cdebyte.com for confirmation.

Can I apply for an invoice?

Send your request to ebyteiot@cdebyte.com and mark your order number like #3188, we will make the invoice for you quickly.

What if I bought the wrong product model?

  1. If your order has not been shipped, email us immediately to change the item or get a refund to place a new order.
  2. If your order has already been shipped, please contact us within 30 days to apply for return or refund. More Returns & Refunds Policies

What if the package is detained or sent back by customs?

We will refund you immediately after receiving the goods, or arrange redelivery twice.

How to solve other technical problems?

Contact online support staff or send emails to ebyteiot@cdebyte.com. Our professional engineers will help you fix all technical issues.

How to contact us?

Email: ebyteiot@cdebyte.com.

Phone: +86-028-61543675

Fax: 0086-028-64146160

E91-DTU series is an industrial-grade LoRa RS485 wireless data transmitter featuring up to 37dBm output, IP67 waterproof protection, and Modbus protocol support for high-reliability, long-range communication in harsh environments.

Parameter Specifications
Product Models E91-DTU(400SL30) / E91-DTU(900SL30) / E91-DTU(400SL37)
Frequency Range 410.125-493.125 MHz / 850.125-930.125 MHz
Transmit Power 30dBm (1W) / 37dBm (5W) Adjustable
Communication Interface RS485 (5-pin M12 Waterproof Connector)
Ingress Protection IP67 (Sealed with Silicone O-ring and Resin Potting)
Operating Voltage 8V - 28V DC (Standard 12V/24V Industrial Power)
Logic Support Modbus RTU, LBT, RSSI, AT/HEX Commands

 

Download Manual

 

 

E91-DTU LoRa RS485 Wireless Modem Overview - EBYTE

E91-DTU Industrial LoRa DTU Product Appearance

E91-DTU Dimensions and Mechanical Drawing

E91-DTU IP67 Waterproof Structure and M12 Connector

E91-DTU RS485 Wiring Diagram and Pin Definition

E91-DTU LoRa Communication Parameters Configuration

E91-DTU Modbus RTU Protocol Support and AT Command Interface

E91-DTU LBT Listen Before Talk and RSSI Monitoring Feature

E91-DTU 30dBm vs 37dBm Transmission Power Comparison

E91-DTU Long Range LoRa Communication Test and Coverage

E91-DTU Industrial IoT Deployment and System Architecture

Application

  • Offshore Oil & Gas Extraction: Utilizing the 37dBm (5W) high-power output, the E91-DTU overcomes signal attenuation caused by dense steel structures and multi-path interference on drilling platforms, ensuring stable telemetry data transmission over several kilometers without additional repeaters.

  • Precision Agriculture & Smart Irrigation: With an IP67-rated flame-retardant housing and M12 waterproof connectors, the device is deployed in open fields to manage solenoid valves. The 30dBm LoRa modulation ensures reliable control signals penetrate through dense foliage and uneven terrain across large-scale plantations.

  • Distributed Photovoltaic (PV) Monitoring: Integrated into solar farm inverters via the RS485 interface, the E91-DTU uses Modbus RTU transparency to transmit real-time voltage and current data to a central gateway. The built-in LBT (Listen Before Talk) functionality prevents data collisions in high-density sensor environments.

E91-DTU LoRa RS485 DTU Application Scenarios - Oil Gas Agriculture Solar

FAQ

Q: How does the power supply ripple affect the RF performance of the E91-DTU(400SL37)?

A: For a 5W (37dBm) high-power transmitter, the instantaneous current can peak significantly during transmission. We recommend a power supply capable of delivering at least 2A with a ripple voltage below 100mV. Excessive ripple can lead to phase noise in the frequency synthesizer and potentially cause the LoRa spread spectrum signal to deviate from the center frequency, reducing the effective receiver sensitivity at the remote end.

Q: What is the significance of the 50-ohm impedance matching for the external antenna?

A: The RF output stage of the E91-DTU is optimized for a 50-ohm characteristic impedance. If the connected antenna or coaxial cable has a high Voltage Standing Wave Ratio (VSWR > 1.5), a portion of the 30-37dBm power will be reflected back to the module as heat. This not only reduces the radiated power and communication range but also increases the thermal stress on the power amplifier (PA) transistor, potentially shortening the hardware lifespan.

Q: How does the Listen Before Talk (LBT) feature improve channel efficiency in industrial Modbus networks?

A: LBT is a carrier sense mechanism where the E91-DTU monitors the RSSI level of the current channel before initiating a transmission. If the detected noise floor exceeds a predefined threshold (typically -80dBm), the module backsoff to avoid a packet collision. This is critical in Modbus networks where multiple nodes share the same frequency, as it significantly reduces the packet error rate (PER) caused by overlapping RF emissions.

Q: What are the logic level requirements for the RS485 interface on the E91-DTU?

A: The device utilizes a standard RS485 differential signaling transceiver. It interprets a differential voltage (VA - VB) greater than +200mV as a logic high and less than -200mV as a logic low. The interface includes built-in ESD protection and high-level isolation, allowing it to interface directly with industrial PLC ports or SCADA systems without the need for external pull-up or pull-down resistors in most standard bus lengths.

Specifications

E91-DTU(400SL30), E91-DTU(400SL37), E91-DTU(900SL30)

Воскресенье понедельник вторник среда четверг пятница суббота
Январь, февраль, март, апрель, май, июнь, июль, август, сентябрь, октябрь, ноябрь, декабрь
Недостаточно доступных предметов. Осталось только [max] .
Добавить в список желанийПросмотр списка желанийУдалить список желаний
Корзина

Ваша корзина пуста.

Return To Shop

Добавить примечание к заказуИзменить примечание к заказу
Оценить доставку
Добавить купон

Оценить доставку

Добавить купон

Код купона будет работать на странице оформления заказа

E91-DTU LoRa RS485 Wireless Modem 30-37dBm IP67 Modbus

E91-DTU(400SL30)
E91-DTU(400SL30)
$27.30