Ebyte PN1 Series PROFINET to Modbus RTU Gateway 4/8 Port RS485 – Ebyte Official Store - IoT Module Manufacturer

Ebyte PN1 Series PROFINET to Modbus RTU Gateway 4/8 Port RS485 DIN-Rail GSDML

$89.00

Shipping calculated at checkout.

The Ebyte PN1 series is an industrial-grade PROFINET to Modbus RTU gateway equipped with 4 or 8 isolated RS485 serial ports and dual 10/100M RJ45 switch interfaces, delivering real-time bidirectional data... Read more

Three Protections: The shell adopts three-proof coating, which is Anti-Fungal, Anti-Humidity, and Anti-Salt Spray.

Shipping: Free Air Shipping Over $89.99(China Post only)If the China post cannot deliver, other logistics need to pay extra postage delivery

Ship From: China EBYTE Manufacturer Factory

Bulk Purchase Tips: Please confirm the firmware version of the test sample with the salesperson before purchasing

Order today. Get it and , hoursminutes

SKU: PN1-D41PH

  • PN1-D41PH
  • PN1-D81PH
Will not ship until [19041994]
$89.00
Out of stock

Guaranteed Safe Checkout

paypalvisadiscovermaestroamerican express

Ebyteiot provides invoices. Bulk order discounts. 24/7 tech support, Manuals and certifications available. Product Selection Guide Download: IoT Module&Modem Selection Guide.pdf

Every day, EBYTEIOT serves hundreds of clients worldwide, ensuring that we always remain responsive.

Free Shipping Terms:  

1、Free shipping only for wireless modules on orders over $89.99.

2、Orders containing Modem, fiberglass antennas, magnetic base antennas or power supply modules are not eligible for free shipping (overweight, magnetic or battery-equipped goods).

3、Due to the temporary inability of postal channels to ship to Europe and the United States, goods to Europe and the United States will be delivered via Yanwen Express Line. Please be aware that additional shipping costs may apply to orders to more remote areas.

4、We offer shipping insurance in partnership with xcottonsp for all orders.
Simply select the shipping insurance option at checkout. Should your order be undeliverable or lost in transit, you will be reimbursed for the full order value. For more information, please visit:

For consumers wishing to file a claim regarding Shipping Protection, Consumers wishing to file a claim regarding shipping protection may contact Xcotton via any of the following methods:
1. Click the "File a claim" option within the confirmation email received after purchase (subject line: "Xcotton Shipping Protection Placed Successfully").
2. Visit this link to file a claim: https://sp.xcottons.com/parcel#/parcel/parcel-login
3. Contact us via email at:  support@xcottons.com.
4. Claims FAQ:https://sp.xcottons.com/#/more/SPDL5
5. Xcotton Terms and Conditions of Use:https://www.xcottons.com/#/terms/SP-delay

 

Total time = processing time + shipping time (shipping time is business days)

Processing time = the time between placing an order and us shipping it.

Shipping time = the time it takes for your order to be shipped and delivered to you.

Processing time: 7 working days

Shipping time: 7-30 working days by China Post Air Mail.

We offer express delivery via DHL, FedEx, UPS and more. Extra shipping fees apply: https://ebyteiot.com/products/ebyte-dedicated-link-for-paying-postage

 

Important Reminder:

(Shipment may take several months at maximum due to uncontrollable factors including wars, geological disasters, bad weather and customs clearance.)

 

Please be advised that we do not deliver to

  • Cuba
  • Islamic Republic of Iran
  • Democratic People's Republic of Korea (North Korea).
  • Sudan
  • Syria
  • Venezuela
  • Yemen
  • Colombia
  • Israel

We apologize for any inconvenience this may cause.

 

Cancel order

We accept order cancellations before the product ships. If your order is cancelled, you will receive a full refund. If the product has already been shipped, the buyer can initiate a return or refund request within 30 calendar days of receiving the goods.


Returns

We accept product returns. Customers have the right to request a return within 30 days of receipt of the product. To be eligible for a return, your item must be unused and in the same condition you received it. It must also be in its original packaging. To complete your return, we require a receipt or proof of purchase.

If the return is caused by the consumer, the consumer will bear the shipping costs. The exact cost depends on the courier company you choose.

If the product is damaged or unusable due to our fault, such as product or transportation reasons, please contact EBYTE: ebyteiot@cdebyte.com. After communication with our technical staff, we will arrange for a reissue or refund.


Refund

Once your return has been received and inspected, we will send you a delivery notification via email. We will also notify you of approval or rejection of the refund. If you're approved, your refund will be processed and automatically credited to your credit card or original payment method within 15 business days.


Contact

Contact our customer service at ebyteiot@cdebyte.com.

Tel: +086 028 61543675

Return address: Building B5, No. 199, West District Avenue, High Tech West District Chengdu, China.

 

Auto-download documents via Ebyte official website link:

The Ebyte PN1 series is an industrial-grade PROFINET to Modbus RTU gateway equipped with 4 or 8 isolated RS485 serial ports and dual 10/100M RJ45 switch interfaces, delivering real-time bidirectional data mapping to Siemens S7-1200/1500 PLCs with 4ms cycle times via standard GSDML integration in TIA Portal, featuring 32 commands per port, 3.9Mbps high-speed serial baud rates, DC 8~28V wide voltage input, and conformal coating protection for harsh industrial automation and SCADA systems.

Key Features & Advantages

  • Seamless PROFINET RT to Modbus RTU Bidirectional Conversion: Maps downstream Modbus slave device data directly into PLC I/O memory spaces with deterministic communication cycles as fast as 4ms, completely eliminating custom PLC serial communication code.
  • High-Density Multi-Port RS485 Architecture (4 or 8 Independent Channels): Available in 4-port (PN1-D41PH) and 8-port (PN1-D81PH) configurations, supporting up to 32 Modbus read/write commands per channel and enabling centralized polling of up to 256 RS485 slave devices.
  • Zero-Programming GSDML Integration in TIA Portal & STEP 7: Simply import the official Ebyte GSDML XML device description file into Siemens TIA Portal to configure baud rates, slave IDs, register addresses, and polling intervals visually through modular hardware configuration.
  • Industrial-Grade Ruggedness with Conformal Coating & Dual RJ45 Switch: Features integrated dual 10/100M Ethernet ports supporting daisy-chain line topology, wide operating voltage (DC 8~28V with reverse polarity protection), standard 35mm DIN-rail mount, and military-grade conformal coating (anti-mold, anti-moisture, anti-salt spray).

Core Specifications

Parameter Specification / Value
Fieldbus Protocol Standard PROFINET Protocol (Real-Time / RT Class 1)
Network Interfaces Dual RJ45 Ethernet Ports (PN1 / PN2), 10/100 Mbps Auto-Negotiation (Built-in Switch)
Min PROFINET Cycle Time Up to 4 ms
Serial Channels & Interfaces 4x RS485 (PN1-D41PH) / 8x RS485 (PN1-D81PH), 5.08mm Industrial Pluggable Screw Terminals
Serial Protocol & Baud Rate Modbus RTU Master Mode, Baud Rate: 1200 ~ 3.9M bps (Customizable parity/stop bits)
Command Capacity Supports up to 32 Modbus commands per RS485 channel (modular GSDML loading)
Operating Voltage & Power DC 8 ~ 28V (Reverse Polarity Protection), Typical Power Consumption: 2 ~ 3 W
Termination Resistor Integrated 120 Ohm matching resistor per port (short-circuit bridgeable R-pin)
Environmental Protection Three-Proof Conformal Coating (Anti-Mold, Anti-Moisture, Anti-Salt Spray)
Operating Temperature & Humidity -40 to +85 deg C, 5% ~ 95% RH (Non-condensing)
Mounting & Enclosure Standard 35mm DIN-Rail, 111 * 40 * 120 mm (L * W * H), Weight: 450 g

Product Selection Guide

Notice for Selection: Please select between 4-port (PN1-D41PH) and 8-port (PN1-D81PH) models based on the total quantity of RS485 slave instruments and Modbus polling nodes required in your cabinet layout.

Model SKU PROFINET Ports RS485 Channels Max Modbus Commands Power Supply Mounting Method Dimensions
PN1-D41PH 2x RJ45 (Cascade Switch) 4 Channels (Isolated) 128 Commands (32/port) DC 8 ~ 28V 35mm DIN-Rail 111 * 40 * 120 mm
PN1-D81PH 2x RJ45 (Cascade Switch) 8 Channels (Isolated) 256 Commands (32/port) DC 8 ~ 28V 35mm DIN-Rail 111 * 40 * 120 mm

Ebyte PN1 Series PROFINET Modbus Gateway Detail - 1_01.jpg

Ebyte PN1 Series PROFINET Modbus Gateway Detail - 1_02.jpg

Ebyte PN1 Series PROFINET Modbus Gateway Detail - 1_03.jpg

Ebyte PN1 Series PROFINET Modbus Gateway Detail - 1_04.jpg

Ebyte PN1 Series PROFINET Modbus Gateway Detail - 1_05.jpg

Ebyte PN1 Series PROFINET Modbus Gateway Detail - 1_07.jpg

Ebyte PN1 Series PROFINET Modbus Gateway Detail - 1_08.jpg

Ebyte PN1 Series PROFINET Modbus Gateway Detail - 1_09.jpg

Ebyte PN1 Series PROFINET Modbus Gateway Detail - 1_10.jpg

Ebyte PN1 Series PROFINET Modbus Gateway Detail - 1_11.jpg

Ebyte PN1 Series PROFINET Modbus Gateway Detail - 1_12.jpg

Ebyte PN1 Series PROFINET Modbus Gateway Detail - 2_01.jpg

Ebyte PN1 Series PROFINET Modbus Gateway Detail - 2_02.jpg

Ebyte PN1 Series PROFINET Modbus Gateway Detail - 2_03.jpg

Ebyte PN1 Series PROFINET Modbus Gateway Detail - 2_04.jpg

Ebyte PN1 Series PROFINET Modbus Gateway Detail - 2_05.jpg

Ebyte PN1 Series PROFINET Modbus Gateway Detail - 2_06.jpg

Ebyte PN1 Series PROFINET Modbus Gateway Detail - 2_07.jpg

Ebyte PN1 Series PROFINET Modbus Gateway Detail - 2_08.jpg

Ebyte PN1 Series PROFINET Modbus Gateway Detail - 2_09.jpg

Ebyte PN1 Series PROFINET Modbus Gateway Detail - 3_01.jpg

Ebyte PN1 Series PROFINET Modbus Gateway Detail - 3_02.jpg

Ebyte PN1 Series PROFINET Modbus Gateway Detail - 3_03.jpg

Ebyte PN1 Series PROFINET Modbus Gateway Detail - 3_04.jpg

Ebyte PN1 Series PROFINET Modbus Gateway Detail - 3_05.jpg

Ebyte PN1 Series PROFINET Modbus Gateway Detail - 3_06.jpg

Ebyte PN1 Series PROFINET Modbus Gateway Detail - 3_07.jpg

Industrial Installation & Wiring

The PN1 series is housed in a robust flame-retardant industrial enclosure measuring 111 * 40 * 120 mm with an integrated 35mm standard DIN-rail mounting clip. Dual RJ45 ports (PN1 / PN2) provide 10/100M Ethernet switching to support daisy-chain line topologies without extra external switches. Field serial connections utilize heavy-duty 5.08mm pluggable screw terminals. Each channel provides dedicated RS485 differential signals (A/B/G) and optional internal 120 Ohm termination resistor activation pins (R). Wide DC 8~28V power terminals feature polarity reverse protection.

Ebyte PN1 Series Industrial Wiring & Terminal Definition - 3_08.jpg

Ebyte PN1 Series Industrial Wiring & Terminal Definition - 3_09.jpg

Practical Application Scenarios

1. Siemens S7 PLC Integration for Factory Automation & CNC Cells

In modern automotive assembly lines and CNC machining plants running Siemens S7-1200 / S7-1500 controllers, legacy frequency inverters, servo drives, and temperature controllers communicate over Modbus RTU. The PN1 gateway seamlessly bridges all serial slave telemetry directly into PLC process image memory (I/Q tags) with deterministic 4ms cycles, enabling unified PLC supervisory control without adding expensive serial communication modules.

2. Power Distribution & Substation Multi-Meter SCADA Data Aggregation

Electrical substations and power distribution cabinets deploy dozens of digital power meters, multi-function relays, and circuit breakers over RS485. Utilizing the 8-channel PN1-D81PH gateway, engineers can segment RS485 buses across independent isolated ports, polling up to 256 Modbus data points simultaneously and streaming real-time voltage, current, and active power metrics up to the PROFINET SCADA dispatch system.

3. Solar Photovoltaic Inverter & Battery Energy Storage (BESS) Monitoring

Utility-scale solar farms and commercial energy storage containers require continuous parameter acquisition from solar string inverters, battery management systems (BMS), and DC combiners. With high-speed 3.9Mbps serial baud rate support, wide DC 8~28V power compatibility, and conformal coating against outdoor condensation, the PN1 gateway ensures uninterrupted energy telemetry in harsh outdoor cabinets.

4. HVAC, Building Automation & Centralized Chiller Plant Control

Commercial building management systems (BMS) integrate multi-brand chillers, variable air volume (VAV) controllers, and air handling units (AHUs). The PN1 gateway aggregates distributed field sensor data and maps damper positions, chilled water temperatures, and flow rates into the master PROFINET PLC architecture, optimizing energy efficiency across entire facility floors.

 

FAQ Section

1. How do I configure the PN1 gateway in Siemens TIA Portal?

Configuration requires no code programming. Simply import the provided Ebyte GSDML XML file into TIA Portal (Options -> Manage general station description files), drag the PN1 gateway from the hardware catalog into your PROFINET network view, assign a device name/IP, and insert desired modular Modbus read/write command submodules under the device slots.

2. How do I activate the built-in 120 Ohm termination resistor on RS485 ports?

Each RS485 channel features dedicated A, B, R, and G terminals. To enable the onboard high-stability 120 Ohm termination resistor at bus endpoints, simply jumper the R pin and B pin together on the terminal block, eliminating the need for external dangling resistors.

3. Can the dual RJ45 Ethernet ports be used for daisy-chain line topology?

Yes. The PN1 gateway features an integrated two-port Ethernet switch on PN1 and PN2. This allows you to daisy-chain multiple PROFINET devices along a single network line, significantly cutting industrial Ethernet switch costs and simplifying field cabinet cabling.

4. What protection does the conformal coating provide in harsh environments?

All internal circuit boards are sprayed with high-grade industrial conformal coating providing comprehensive protection against moisture, condensation, mold, and airborne salt spray. Combined with -40°C to +85°C industrial temperature tolerance, the gateway operates reliably in coastal wind farms, wastewater plants, and chemical processing facilities.

SKU

PN1-D41PH, PN1-D81PH

Disclaimer:This product is strictly prohibited for use in military applications and scenarios related to life safety. The user shall be fully liable for any unauthorized use.

Sunday,Monday,Tuesday,Wednesday,Thursday,Friday,Saturday
January,February,March,April,May,June,July,August,September,October,November,December
Not enough items available. Only [max] left.
Add to WishlistBrowse WishlistRemove Wishlist
Shopping cart

Your cart is empty.

Return To Shop

Add Order NoteEdit Order Note
Estimate Shipping
Add A Coupon

Estimate Shipping

Add A Coupon

10%OFF Code: ebyteiot ,Available for any order ,Coupon code will work on checkout page

Ebyte PN1 Series PROFINET to Modbus RTU Gateway 4/8 Port RS485 DIN-Rail GSDML

PN1-D41PH
PN1-D41PH
$89.00