ME31-XEXX0600 6-channel K-type thermocouple temperature acquisition RS485 Modbus module Modbus gateway Support Modbus TCP/RTU protocol [Communication interface]:RJ45, RS485 [Working voltage]:DC 8~28V [Installation method]:Guide rail/screw [Introduction]:ME31-XEXX0600 is a K-type thermocouple temperature acquisition... Weiterlesen

Availability: In Stock

Shipping: Free Air Shipping Over $50

Ship From: China EBYTE Official Factory

Bestellen Sie heute. Holen Sie es sich und , Std.Protokoll
Ausverkauft

Garantiert sichere Kasse

PaypalVisaDiscoverMaestroAmerican Express

Jeden Tag betreut EBYTEIOT Hunderte von Kunden weltweit und stellt sicher, dass wir stets reaktionsfähig bleiben.

Kostenloser Versand: Alle Produktbestellungen mit einem Gesamtwert von mehr als 50 $ sind für den kostenlosen Versand berechtigt.

Gesamtzeit = Bearbeitungszeit + Versandzeit (Versandzeit beträgt Werktage)

Bearbeitungszeit = die Zeit zwischen der Bestellung und dem Versand durch uns.

Versandzeit = die Zeit, die benötigt wird, bis Ihre Bestellung versandt und an Sie geliefert wird.

Bearbeitungszeit: 7 Werktage


Lieferzeit: 7–15 Werktage per China Post Air Mail (kann aufgrund unvorhersehbarer Faktoren wie Wetter und Zollabwicklung bis zu 45 Werktage dauern).

Bitte beachten Sie, dass wir nicht liefern

  • Kuba
  • Islamische Republik Iran
  • Demokratische Volksrepublik Korea (Nordkorea).
  • Sudan
  • Syrien
  • Venezuela
  • Jemen

Wir entschuldigen uns für etwaige Unannehmlichkeiten.

Bestellung stornieren

Wir akzeptieren Stornierungen von Bestellungen, bevor das Produkt versandt wird. Wenn Ihre Bestellung storniert wird, erhalten Sie eine volle Rückerstattung. Wir können Stornierungen von Bestellungen nicht abwehren, wenn das Produkt bereits versandt wurde.


Kehrt zurück

Wir akzeptieren Produktrückgaben. Kunden haben das Recht, innerhalb von 30 Tagen nach Erhalt des Produkts eine Rückgabe zu beantragen. Um Anspruch auf eine Rückgabe zu haben, muss Ihr Artikel unbenutzt und in demselben Zustand sein, in dem Sie ihn erhalten haben. Es muss außerdem in der Originalverpackung sein. Um Ihre Rücksendung abzuschließen, benötigen wir eine Quittung oder einen Kaufbeleg.

Erfolgt die Rücksendung durch den Verbraucher, trägt der Verbraucher die Versandkosten. Die genauen Kosten hängen von dem von Ihnen gewählten Kurierunternehmen ab.

Wenn das Produkt aufgrund unseres Verschuldens, beispielsweise aus Produkt- oder Transportgründen, beschädigt oder unbrauchbar ist, wenden Sie sich bitte an EBYTE: ebyteiot@cdebyte.com. Nach Rücksprache mit unserem technischen Personal veranlassen wir eine Neuausstellung oder Rückerstattung .


Erstattung

Sobald Ihre Rücksendung eingegangen und geprüft ist, senden wir Ihnen eine Lieferbenachrichtigung per E-Mail. Wir werden Sie auch über die Genehmigung oder Ablehnung der Rückerstattung informieren. Wenn Ihre Rückerstattung genehmigt wird, wird Ihre Rückerstattung bearbeitet und innerhalb von 15 Werktagen automatisch Ihrer Kreditkarte oder der ursprünglichen Zahlungsmethode gutgeschrieben.

Kontakt

Kontaktieren Sie unseren Kundenservice unter ebyteiot@cdebyte.com.

Tel.: +086 028 61543675

Rücksendeadresse: Gebäude B5, Nr. 199, West District Avenue, High Tech West District Chengdu, China.

EBYTE product technical manual and detailed parameters download: https://www.cdebyte.com/Product-Selection

ME31-XEXX0600 6-channel K-type thermocouple temperature acquisition RS485 Modbus module Modbus gateway Support Modbus TCP/RTU protocol

[Communication interface]:RJ45, RS485

[Working voltage]:DC 8~28V

[Installation method]:Guide rail/screw

[Introduction]:ME31-XEXX0600 is a K-type thermocouple temperature acquisition module with 6-channel K-type thermocouple temperature acquisition function, supporting the acquisition of 2-wire K-type thermocouple temperature sensors. It also has a display screen to facilitate customers to debug configuration and view temperature on site. The module supports both network and RS485 communication interfaces, and supports Modbus TCP protocol or Modbus RTU protocol for acquisition. It can also be used as a Modbus gateway, automatically sending instructions from non-local Modbus addresses through the serial port/network port, supporting Modbus TCP and Modbus RTU protocol conversion, and conveniently expanding Modbus slave devices.

Category  Name  Parameters
Ethernet parameters Working mode TCP server (up to 4 client accesses)
Local IP 192.168.3.7
Local port 502
Subnet mask 255.255.255.0
Gateway address 192.168.3.1
DHCP Off
Local MAC Determined by the chip (fixed)
Target IP 192.168.3.3
Target port 502
DNS server 114.114.114.114
Active upload Off
Serial port parameters Baud rate 9600bps (8 types)
Check method None
Data bit 8
Stop bit 1
MODBUS Parameters Modbus master-slave Slave
Address 1
Category  Name  Parameters
power supply Working voltage DC8~28V
Power indicator Blue LED indication
Communication Communication interface RJ45, RS485
Baud rate 1200~115200bps (default 9600)
Communication protocol Standard Modbus TCP, Modbus RTU protocol
MODBUS Device address Can be modified through Modbus command, host computer, device button
Temperature collection Number of channels 6-way
Sensor type 2-wire K-type thermocouple temperature sensor
Temperature resolution 0.1℃
Accuracy Normal temperature (25±5℃) condition: ±0.1%±1℃
Full temperature (-40~85℃) condition: ±0.5%±1℃
Collection frequency 1Hz
Collection display OLED screen display
other Product size 121mm * 72mm * 34mm (length * width * height)
Product weight 140 ±5 g
Working temperature and humidity -40 ~ +85℃, 5% ~ 95%RH (no condensation)
Installation method Guide rail installation, screw installation

High precision and stability
Parameter Comparison Table
16 core functions
High-precision acquisition
High protection isolation
Real-time temperature display

Key Configuration

RS485 Cascade Expansion

Support 4-way socket link

ModBus Gateway Features
Sonntag,Montag,Dienstag,Mittwoch,Donnerstag,Freitag,Samstag
Januar,Februar,März,April,Mai,Juni,Juli,August,September,Oktober,November,Dezember
Nicht genügend Artikel verfügbar. Nur noch [max] übrig.
Zur Wunschliste hinzufügenWunschliste durchsuchenVon der Wunschliste entfernen
Warenkorb

Ihr Warenkorb ist leer.

Zurück zum Shop

Bestellhinweis hinzufügenBestellhinweis bearbeiten
Versand schätzen
Fügen Sie einen Gutschein hinzu

Versand schätzen

Fügen Sie einen Gutschein hinzu

Der Gutscheincode funktioniert auf der Checkout-Seite

Temperature Acquisition Module 6-way Type K Thermocouple CDEBYTE ME31-XEXX0600 Ethernet RS485 With OLED Display Screen Modbus

$34.95