No — not over the air. The E22-900M22S tunes 850–930 MHz, and the SX1278 tunes 137–525 MHz. The two ranges do not overlap by a single megahertz, so a 433 or 470 MHz SX1278 front end cannot receive an 868 or 915 MHz transmission no matter how the software is configured.

The chip difference is not the obstacle. Both parts implement Semtech's LoRa chirp spread spectrum, and LoRa devices from different chip generations do interoperate when they share a band and match their air parameters. The blocker here is the radio front end, and it is physical.

The short answer

Question

Answer

Do the frequency ranges overlap?

No — 850–930 MHz against 137–525 MHz

Is the modulation compatible?

Yes — both are Semtech LoRa CSS

Can they link as shipped?

No — there is no common channel

Can a band-matched SX127x link?

Yes — with every air parameter matched

LoRa in two lines: a sub-GHz spread-spectrum modulation that trades data rate for processing gain and long range. → Read more: What is LoRa?

Why the band alone rules it out

The E22-900M22S is built on the SX1262 and covers 850–930 MHz, the 868 and 915 MHz ISM bands used in Europe and North America. Its datasheet gives 22 dBm output, −147 dBm sensitivity, an air rate of 0.018–300 kbps, 1.8–3.7 V supply and an SPI interface on a 14 × 20 mm package.

The SX1278 covers 137–525 MHz, which is where 169, 315, 433 and 470 MHz systems live. Semtech specifies +20 dBm output, −148 dBm sensitivity, a 168 dB link budget, SF6–SF12 and 7.8–500 kHz bandwidth.

Those two tuning ranges are disjoint. A receiver's sensitivity figure assumes the signal arrives inside its passband; outside it, the front end attenuates rather than demodulates. Software cannot recover a signal the RF chain never passed.

This is also why the question keeps coming up: both modules are sold as "LoRa," and the name describes the modulation, not the band.

The chip family is not the problem

SX1262 and SX1278 are different silicon generations, but over the air they speak the same LoRa physical layer. Interoperability fails on configuration, not on part number.

A link closes only when all of the following match on both ends:

Parameter

Must match

Note

Frequency and bandwidth

Yes

125, 250 or 500 kHz must be identical

Spreading factor

Yes

SX1262 supports SF5–SF12; SX1278 supports SF6–SF12

Coding rate

Yes

4/5 through 4/8

Sync word

Yes

private-network and public LoRaWAN sync words differ

Header mode

Yes

explicit versus implicit; implicit needs a fixed length

Payload CRC

Yes

enabled or disabled on both sides

IQ inversion

Yes

set identically, or packets arrive inverted and fail

Low-data-rate optimisation

Yes

enable consistently at SF11 and SF12 with 125 kHz

Preamble length

Yes

long enough for the receiver's detector

One mismatch produces the same symptom: RSSI looks healthy, packets never decode. If you are debugging that, check the list in order — spreading factor and IQ inversion account for most failures.

Note the SF5 row. SX1262 supports spreading factor 5 and SX1278 does not, so an E22 set to SF5 cannot be heard by any SX1278 even in a shared band. Keep both ends at SF6 or above.

Power asymmetry is not a problem: 22 dBm against 20 dBm is a 2 dB difference in one direction, well inside a 168 dB link budget.

Pick a pair that shares a band

Since the E22-900M22S and the SX1278 have no common frequency, one of the two has to change. Two clean options:

Keep the 868/915 MHz side. Pair the SX1262 module with an SX1276, which covers 137–1020 MHz and includes 868 and 915 MHz. Same modulation, same parameter rules, a band that overlaps.

Keep the 433/470 MHz side. Pair the SX1278 with an E22-400M22S, built on the SX1268 and covering 410–493 MHz. This keeps the Ebyte module family and the SPI driver model while moving to a band the SX1278 can hear. The E22-M series selection guide lists both the 400 and 900 MHz variants with identical pinouts.

The rule is simple: choose the band first, then the chip. Choosing the chip first is what produces this question.

Configuration checklist for the chosen pair

  1. Confirm both datasheets state the same centre frequency, and set the channel inside both ranges.
  1. Set bandwidth, spreading factor, coding rate, preamble and sync word to identical values.
  1. Match header mode, payload CRC and IQ inversion.
  1. At SF11 or SF12 with 125 kHz, enable low-data-rate optimisation on both ends.
  1. Send a fixed 8-byte test payload first; a known length removes implicit-header ambiguity.
  1. Verify with RSSI and packet-CRC counters on the receiving side, not with a serial terminal alone.

FAQ

Does SX1262 talk to SX1278 at all? Yes, in a shared band and with matched parameters. Both implement LoRa CSS, so the waveform is the same. The practical limits are that SX1278 has no SF5 and that every air parameter must be set identically.

Can I retune the E22-900M22S down to 433 MHz? No. Its RF front end and matching network cover 850–930 MHz; the tuning range is a hardware property, not a register setting. For 433 or 470 MHz, use the E22-400M22S, which is built on the SX1268 for 410–493 MHz.

Will a 22 dBm module damage a 20 dBm one at close range? Not through the air at normal separation, but do not park the antennas together. The E22-900M22S lists a blocking power of 10 dBm, so a transmitter running 22 dBm a few centimetres away can overload the receiver. Separate the antennas or attenuate during bench tests.