Ebyte PN1-S25T Siemens PROFINET to Modbus TCP/RTU Gateway Module 3.3V – Ebyte Official Store - IoT Module Manufacturer

Ebyte PN1-S25T Siemens PROFINET to Modbus TCP/RTU Gateway Module 3.3V TTL

$22.90

Shipping calculated at checkout.

The Ebyte PN1-S25T is an industrial-grade PROFINET to Modbus TCP/RTU gateway module operating at 3.3V TTL, designed for seamless, code-free PLC integration in Siemens TIA Portal and STEP 7 via GSD... Read more

Shipping: Free Air Shipping Over $89.99(China Post only)If the China post cannot deliver, other logistics need to pay extra postage delivery

Ship From: China EBYTE Manufacturer Factory

Bulk Purchase Tips: Please confirm the firmware version of the test sample with the salesperson before purchasing

Order today. Get it and , hoursminutes

SKU: PN1-S25

  • PN1-S25
  • PN1-S25-TB
  • PN1-S25T
  • PN1-S25T-TB
Will not ship until [19041994]
$22.90
SKU: PN1-S25N/A

Guaranteed Safe Checkout

paypalvisamasteramerican expressdiscoverjcbdiners clubpix

Ebyteiot provides invoices. Bulk order discounts. 24/7 tech support, Manuals and certifications available. Product Selection Guide Download: IoT Module&Modem Selection Guide.pdf

When will the order be shipped?

We have sufficient goods in stock. We will send out goods within 1 to 2 working days after payment. We use China Post Air Mail as our regular shipping method. It normally takes 7 to 15 working days to arrive. Free shipping only for wireless modules on orders over $89.99. excluding Modem, fiberglass antennas and power supplies. More Shipping Policies

How can I track my shipment?

After shipment, you will receive an email with the tracking number, such as LZ4177733XXCN. Check logistics status here: https://www.17track.net/en

How to buy samples priced at $0.1?

You can mix different sample types. Each order can buy maximum 2 pieces. Buy $0.1 Sample

Where can I download product manuals?

You can download related documents directly on each product page. More materials:https://www.cdebyte.com/Product-Selection

How about product performance?

All EBYTE products support return and exchange within 30 days. Our items work steadily and you do not need to worry about after-sales problems.

What certifications do the products own?

Our goods have passed CE, FCC and RoHS certifications. You can download certification files on product pages directly, fully meeting compliance requirements.

What is the price for bulk purchase?

You can place bulk orders directly online. Large orders of 50, 200, 500, 1000 pieces and above enjoy factory discounted prices. Shipping cost can be checked on the page. Delivery takes 7 to 15 working days.

Why check firmware version before bulk order?

If you buy products in large quantity, please confirm the firmware version of bulk goods is the same as your test sample. This ensures normal operation of your project.
If you cannot confirm the version number, contact online customer service or send emails to ebyteiot@cdebyte.com for confirmation.

Can I apply for an invoice?

Send your request to ebyteiot@cdebyte.com and mark your order number like #3188, we will make the invoice for you quickly.

What if I bought the wrong product model?

  1. If your order has not been shipped, email us immediately to change the item or get a refund to place a new order.
  2. If your order has already been shipped, please contact us within 30 days to apply for return or refund. More Returns & Refunds Policies

What if the package is detained or sent back by customs?

We will refund you immediately after receiving the goods, or arrange redelivery twice.

How to solve other technical problems?

Contact online support staff or send emails to ebyteiot@cdebyte.com. Our professional engineers will help you fix all technical issues.

How to contact us?

Email: ebyteiot@cdebyte.com.

Phone: +86-028-61543675

Fax: 0086-028-64146160

Auto-download documents via Ebyte official website link:

The Ebyte PN1-S25T is an industrial-grade PROFINET to Modbus TCP/RTU gateway module operating at 3.3V TTL, designed for seamless, code-free PLC integration in Siemens TIA Portal and STEP 7 via GSD files, offering bi-directional memory mapping, Modbus status byte monitoring, dual RJ45/RS485 connectivity on its PN1-S25T-TB evaluation kit, and compact 27x27x3mm surface-mount form factor for industrial automation networks.

Parameter Specification
Protocol Support PROFINET I/O to Modbus TCP / Modbus RTU Slave/Master
Communication Interface 3.3V UART (TTL Level)
Operating Voltage DC 3.3V
Configuration Method GSD File Integration (TIA Portal / STEP 7)
Dimensions & Weight 27 x 27 x 3 mm | 4g (±1g)

Key Features

  • Code-Free PLC Integration: Native GSD file import enables plug-and-play mapping of Modbus data registers straight into Siemens TIA Portal or STEP 7 without writing custom communication code.

  • Intuitive Memory Mapping: Modbus commands are loaded as standard modular blocks, creating a visual, direct register mapping between Modbus nodes and the Siemens PLC controller.

  • Real-time Diagnostic Monitoring: Built-in status byte loading allows continuous, real-time polling of Modbus device connection integrity directly from the PLC master station.

  • Flexible Prototyping Ecosystem: The PN1-S25T SMT stamp-hole module allows compact PCB design, while the PN1-S25T-TB offers dual Ethernet ports and isolated RS485 for immediate bench testing.

Parameter PN1-S25 PN1-S25-TB PN1-S25T PN1-S25T-TB
Category Profinet to ModBus RTU Module PN1-S25 Test Board Profinet to ModBus RTU/TCP Module PN1-S25T Test Board
Profinet Ethernet Port 10/100 Mbps auto-negotiation 10/100 Mbps auto-negotiation 10/100 Mbps auto-negotiation 10/100 Mbps auto-negotiation
ModBus TCP Ethernet Port 10/100 Mbps auto-negotiation 10/100 Mbps auto-negotiation
Number of Serial Ports Route 2 Route 2 Route 1 Route 1
Operating Voltage DC 3.3V DC 5V DC 3.3V DC 5V
Package Dimensions 24 × 19 × 3.2 mm 88 × 40 × 16.5 mm 27 × 27 × 3.0 mm 100 × 40 × 16.5 mm



Industrial Installation & Wiring

The PN1-S25T SMT module is designed for automated surface-mount assembly on host controller PCBs operating at 3.3V digital logic. For evaluation and field deployments, the PN1-S25T-TB development board provides a standard Type-C 5V power port, terminal block connections for 2-wire RS485 differential communication, and dual RJ45 ports for PROFINET network topology and Modbus TCP bridging.



Practical Application Scenarios

1. Legacy Serial Field Instrument Integration into Siemens S7-1200/1500 PLCs

In factory automation retrofits, legacy RS485 Modbus RTU energy meters and sensor arrays cannot directly communicate with PROFINET industrial Ethernet. Embedded with the PN1-S25T, the gateway translates RS485 serial commands directly into PROFINET IO cyclic data, presenting field parameters to Siemens PLCs via simple GSD file configuration.

2. Multi-Protocol Industrial Ethernet Bridging for Smart Manufacturing

Manufacturing cells often combine Modbus TCP smart actuators and PROFINET control networks. The PN1-S25T-TB test kit acts as a dual-port protocol conversion hub, bridging Modbus TCP traffic from field IP nodes into standard PROFINET I/O controllers without complex network reconfiguration.

3. OEM Embedded PLC Interface Development for Specialized Machinery

Equipment OEMs building customized motor drives, CNC controllers, or thermal management systems can solder the PN1-S25T module directly onto main control boards. This adds native PROFINET slave capabilities to 3.3V microcontroller platforms, expanding market reach to Siemens-dominated industrial environments.

4. Distributed Building Automation & HVAC System Integration

Large-scale building management systems often rely on Modbus RS485 RTU loops for chiller and air handler telemetry. Utilizing Ebyte PN1-S25T gateway modules enables central PLC systems to continuously monitor remote equipment connection health via dedicated PROFINET status bytes for rapid troubleshooting.


FAQ

1. How is the PN1-S25T module configured within Siemens TIA Portal?

Configuration is handled entirely through standard GSD (General Station Description) files provided by Ebyte. Engineers simply import the GSD file into TIA Portal or STEP 7, select the required Modbus command modules, and map the I/O addresses directly to PLC data blocks without writing custom serial driver code.

2. What is the difference between the PN1-S25T module and the PN1-S25T-TB test kit?

The PN1-S25T is a compact (27x27x3mm) 3.3V SMT module intended for direct integration into custom PCB products. The PN1-S25T-TB is a fully equipped evaluation kit that adds a 5V Type-C power input, an RS485 transceiver interface, two RJ45 Ethernet ports, hardware reset buttons, and onboard LED diagnostic indicators for fast prototyping.

3. How does the module detect communication failures with downstream Modbus slave devices?

The PN1-S25T features a configurable status byte function. When enabled in the GSD configuration, the gateway module constantly updates a designated status byte within the PLC I/O map, providing immediate, real-time indication if a Modbus RTU or Modbus TCP slave drops offline or experiences transmission timeouts.

4. Can the PN1-S25T operate simultaneously on 5V logic systems?

The standalone PN1-S25T module operates natively at 3.3V TTL logic. When interfacing with 5V microcontrollers or field buses, external logic level shifters or RS485 transceivers are required. Alternatively, engineers can utilize the PN1-S25T-TB board, which handles 5V power input and onboard level conversion for RS485/RJ45 interfaces.

SKU

PN1-S25, PN1-S25-TB, PN1-S25T, PN1-S25T-TB

Disclaimer:This product is strictly prohibited for use in military applications and scenarios related to life safety. The user shall be fully liable for any unauthorized use.

Sunday,Monday,Tuesday,Wednesday,Thursday,Friday,Saturday
January,February,March,April,May,June,July,August,September,October,November,December
Not enough items available. Only [max] left.
Aggiungi alla lista dei desideriSfoglia la lista dei desideriRimuovi la lista dei desideri
Shopping cart

Your cart is empty.

Return To Shop

Add Order NoteEdit Order Note
Estimate Shipping
Add A Coupon

Estimate Shipping

Add A Coupon

10%OFF Code: ebyteiot ,Available for any order ,Coupon code will work on checkout page

Ebyte PN1-S25T Siemens PROFINET to Modbus TCP/RTU Gateway Module 3.3V TTL

PN1-S25
PN1-S25
$22.90