| Serial No. | Item | Specifications |
| 1 | voltage | DC8~28V, 12V or 24V power supply recommended |
| 2 | Network port specifications | Standard RJ45, supports 10/100Mbps |
| 3 | Network protocol | IP, TCP/UDP, ARP, ICMP, IPv4, MQTT, HTTP |
| 4 | Socket number | 2-way full function |
| 5 | Socket mode | TCP Server, TCP Client, UDP Server, UDP Client, HTTP Client, MQTT Client |
| 6 | TCP Server connection | Supports up to 5 TCP connections |
| 7 | IP acquisition method | Static IP, DHCP |
| 8 | DNS | support |
| 9 | domain name server | Customizable, default 114.114.114.114 |
| 10 | User configuration | Web page configuration, host computer, AT command |
| 11 | Antenna interface | SMA (external thread, internal hole) |
| 12 | Operating temperature | -40 ~ +85℃, industrial grade |
| 13 | Working humidity | 10% ~ 90%, relative humidity, no condensation |
| 14 | Size | 84mm×82mm×25mm |
| 15 | Average weight | 130±5g |
| 16 | Storage temperature | -40~+125℃, industrial grade |
Frequency range and number of channels
| Model specifications | Factory default frequency MHz | Frequency band range MHz | Channel spacing Hz | Number of channels |
| E90-DTU(230SL30)E | 230.125 | 220.125~236.125 | 250K | 0~64 (default 40) half duplex |
| E90-DTU(400SL22)E | 433.125 | 410.125~493.125 | 1M | 0~83 (default 23) half duplex |
| E90-DTU(400SL30)E | ||||
| E90-DTU(900SL22)E | 868.125 | 850.125~930.125 | 1M | 0~80 (default 18) half duplex |
| E90-DTU(900SL30)E |
| Model Specifications | Airspeed Range | Default Parameters |
| E90-DTU(230SL30)E | 2.4、4.8、9.6、15.6Kbps | 2.4Kbps |
| E90-DTU(400SL22)E | 2.4、4.8、9.6、19.2、38.4、62.5Kbps | 2.4Kbps |
| E90-DTU(400SL30)E | ||
| E90-DTU(900SL22)E | 2.4、4.8、9.6、19.2、38.4、62.5 Kbps | 2.4Kbps |
| E90-DTU(900SL30)E |
| Model Specifications | Distance | Remarks |
| E90-DTU(230SL30)E | 10KM | Sunny and open environment, antenna gain 5dBi, antenna height 2.5 meters, air rate 2.4Kbps |
| E90-DTU(400SL22)E | 5KM | Sunny and open environment, antenna gain 5dBi, antenna height 2.5 meters, air rate 2.4Kbps |
| E90-DTU(400SL30)E | 10KM | Sunny and open environment, antenna gain 5dBi, antenna height 2.5 meters, air rate 2.4Kbps |
| E90-DTU(900SL22)E | 5KM | Sunny and open environment, antenna gain 5dBi, antenna height 2.5 meters, air rate 2.4Kbps |
| E90-DTU(900SL30)E | 10KM | Sunny and open environment, antenna gain 5dBi, antenna height 2.5 meters, air rate 2.4Kbps |

Practical Application Scenarios
1. Urban Smart Grid Substation Telemetry and Automated Data Aggregation
In wide-area power distribution networks, regional SCADA control systems must reliably collect data from numerous pole-mounted power quality sensors without line-of-sight propagation paths. By deploying this device as a central master gateway, it utilizes its hardware polling engine to actively gather field diagnostics over the Sub-GHz radio link. The collected telemetry packets are immediately mapped into standard TCP/IP network streams, routing critical grid data directly into the substation control center room.
2. Smart Factory PLC Automation Networks and Industrial Cross-Media Routing
Modern manufacturing floors require high-density wireless bridges between centralized control rooms and moving robotic arms or remote PLCs. System engineers utilize the gateway operating under TCP Server mode to establish direct linkages with discrete LoRa slave terminals over the air. The device acts as an intelligent media converter, consolidating multiple field data streams into a single local area network backbone, which eliminates expensive industrial Fieldbus cabling and slashes factory deployment costs.
3. Petrochemical Cross-Country Pipeline Remote Telemetry to Cloud Environments
Petrochemical flow meters and emergency shut-off valves require secure transmission infrastructures across harsh wilderness settings. Featuring native MQTT and HTTP Client stacks, this gateway bridges local field instruments directly to enterprise IoT cloud platforms without requiring intermediate onsite industrial PCs. Wrapped in a heavy-duty metal enclosure, the device withstands severe outdoor temperature drops and voltage fluctuations, ensuring long-term unattended remote field operations.
FAQ Section
1. How does the E90-DTU(900SL30)E execute autonomous Modbus polling without host processing overhead?
The wireless gateway incorporates an integrated hardware Modbus protocol translation layer. When configured as a master node, the device automatically coordinates the timing, commands, and target registry structures for downstream field transceivers over the LoRa spread spectrum link. It gathers data from remote wireless nodes independently and maps the returned packets directly into standard Modbus TCP frames over the RJ45 interface, minimizing network bandwidth consumption and relieving main PLC or host computer processing overhead.
2. What are the engineering deployment benefits of having a 2-way independent Socket architecture?
The 2-way independent Socket structure allows the device to process data streams towards two separate destination endpoints or cloud servers simultaneously using distinct protocol types. For example, Socket 1 can be assigned to run as an MQTT Client to upload live industrial telemetry parameters directly to enterprise cloud platforms, while Socket 2 acts as a standard TCP Client backing up raw serial hex records to a localized backup server within the plant LAN.
3. What electrical guidelines should be followed to ensure the gateway handles transient voltage spikes in heavy industries?
The gateway features a robust industrial-grade wide voltage input layout accepting DC 8V to 28V. When configuring the system cabinet, it is highly recommended to feed the device using a dedicated 12V or 24V industrial rail-mounted power supply. To guard against electromagnetic interference, transient switching surges, or common-mode spikes caused by high-power electric motors, an external surge protector should be connected upstream on the DC input power lines.
4. Can multiple client nodes communicate concurrently when the gateway is running in TCP Server mode?
Yes, the gateway provides comprehensive support for multi-client connections. When running under TCP Server mode, the integrated network controller allows up to 6 independent client connections simultaneously. The device acts as a central hub, parsing incoming network traffic from different client IPs, checking data integrity via internal check routines, and transmitting the structured serial data packets down to target wireless nodes across the 915MHz LoRa field array.