Ebyte EID091 Series ECAN-F02 Industrial CAN-FD to RS485 Ethernet Conve – Ebyte Official Store - IoT Module Manufacturer

Ebyte EID091 Series ECAN-F02 Industrial CAN-FD to RS485 Ethernet Converter

$66.73

Shipping calculated at checkout.

The Ebyte ECAN-F02 and EID091 series are industrial-grade CAN-FD protocol converters featuring microsecond-latency CAN-to-fiber bidirectional conversion, isolated CAN-FD to RS485 translation with 5 operating modes, and 3-channel CAN-FD to Ethernet bridging... Read more

Shipping: Free Air Shipping Over $89.99(China Post only)If the China post cannot deliver, other logistics need to pay extra postage delivery

Ship From: China EBYTE Manufacturer Factory

Bulk Purchase Tips: Please confirm the firmware version of the test sample with the salesperson before purchasing

Order today. Get it and , hoursminutes

Specifications: ECAN-F02

  • ECAN-F02
  • EID091-A101
  • EID091-A101-S
  • EID091-A601
  • EID091-A601-S
Se enviarán después de [19041994]
$66.73
Sin existencias

Ebyteiot provides invoices. Bulk order discounts. 24/7 tech support, product selection & project solutions. Manuals and certifications available for download.

SKU: ECAN-F02No disponibleEtiquetas: RS485

Guaranteed Safe Checkout

paypalvisamasteramerican expressdiscoverjcbdiners clubpix

When will the order be shipped?

We have sufficient goods in stock. We will send out goods within 1 to 2 working days after payment. We use China Post Air Mail as our regular shipping method. It normally takes 7 to 15 working days to arrive. Free shipping applies to orders over $89.99, excluding fiberglass antennas and power supplies. More Shipping Policies

How can I track my shipment?

After shipment, you will receive an email with the tracking number, such as LZ4177733XXCN. Check logistics status here: https://www.17track.net/en

How to buy samples priced at $0.1?

You can mix different sample types. Each order can buy maximum 2 pieces. Buy $0.1 Sample

Where can I download product manuals?

You can download related documents directly on each product page. More materials:https://www.cdebyte.com/Product-Selection

How about product performance?

All EBYTE products support return and exchange within 30 days. Our items work steadily and you do not need to worry about after-sales problems.

What certifications do the products own?

Our goods have passed CE, FCC and RoHS certifications. You can download certification files on product pages directly, fully meeting compliance requirements.

What is the price for bulk purchase?

You can place bulk orders directly online. Large orders of 50, 200, 500, 1000 pieces and above enjoy factory discounted prices. Shipping cost can be checked on the page. Delivery takes 7 to 15 working days.

Why check firmware version before bulk order?

If you buy products in large quantity, please confirm the firmware version of bulk goods is the same as your test sample. This ensures normal operation of your project.
If you cannot confirm the version number, contact online customer service or send emails to ebyteiot@cdebyte.com for confirmation.

Can I apply for an invoice?

Send your request to ebyteiot@cdebyte.com and mark your order number like #3188, we will make the invoice for you quickly.

What if I bought the wrong product model?

  1. If your order has not been shipped, email us immediately to change the item or get a refund to place a new order.
  2. If your order has already been shipped, please contact us within 30 days to apply for return or refund. More Returns & Refunds Policies

What if the package is detained or sent back by customs?

We will refund you immediately after receiving the goods, or arrange redelivery twice.

How to solve other technical problems?

Contact online support staff or send emails to ebyteiot@cdebyte.com. Our professional engineers will help you fix all technical issues.

How to contact us?

Email: ebyteiot@cdebyte.com.

Phone: +86-028-61543675

Fax: 0086-028-64146160

Auto-download documents via Ebyte official website link:

The Ebyte ECAN-F02 and EID091 series are industrial-grade CAN-FD protocol converters featuring microsecond-latency CAN-to-fiber bidirectional conversion, isolated CAN-FD to RS485 translation with 5 operating modes, and 3-channel CAN-FD to Ethernet bridging supporting TCP/UDP protocols, all engineered with wide DC inputs and rugged anti-corrosion conformal coatings for heavy-duty automation.

Product Model Protocol Conversion Type Interface Configuration Operating Voltage Isolation Status Dimensions Core Features
ECAN-F02 CAN(FD) to Fiber Optic 1x CAN, 2x SC Fiber (Single-mode dual-core) DC 9 to 36V Power + Signal Independent Isolation 113 x 105 x 25 mm Microsecond latency, lossless bidirectional conversion, conformal coating
EID091-A101-S CAN-FD to RS485 CAN-FD, RS485 (Spring Terminals) DC 8 to 28V Isolated Version 106 x 28 x 27 mm ISO & Bosch CANFD compatible, CAN 2.0 A/B compliant, 5 working modes, conformal coating
EID091-A101 CAN-FD to RS485 CAN-FD, RS485 (Spring Terminals) DC 8 to 28V Isolated Version 106 x 28 x 27 mm ISO & Bosch CANFD compatible, CAN 2.0 A/B compliant, 5 working modes, conformal coating
EID091-A601-S CAN-FD to Ethernet 3-Channel CAN-FD, RJ45 Ethernet DC 8 to 28V Non-Isolated Version 100.7 x 30 x 63 mm Built-in 120 ohms software-configurable resistor, TCP/UDP protocols, ISO & Bosch CANFD, conformal coating
EID091-A601 CAN-FD to Ethernet 3-Channel CAN-FD, RJ45 Ethernet DC 8 to 28V Isolated Version 100.7 x 30 x 63 mm Built-in 120 ohms software-configurable resistor, TCP/UDP protocols, ISO & Bosch CANFD, conformal coating

 

Practical Application Scenarios

1. Ultra-Long Distance Power Grid Substation Telemetry

In high-voltage electrical substations, standard copper CAN networks fail due to immense electromagnetic interference and strict distance limitations. By deploying the ECAN-F02 converter, automation integrators can transition copper CAN-bus topologies directly into single-mode dual-core SC fiber optic lines. This achieves seamless, microsecond-latency bidirectional transparent conversion across massive infrastructure layouts, while the independent power and signal isolation provides ultimate protection against high-voltage surges.

2. Automotive Testing Benches and Diagnostic Data Logging

During powertrain testing and field diagnostic operations, engineers need to bridge high-speed ISO/Bosch CAN-FD vehicle bus networks with legacy industrial RS485 data acquisition equipment. The EID091-A101 and EID091-A101-S modules resolve this by delivering precise protocol translation alongside 5 configurable software working modes. The integration of quick-connect spring terminals dramatically accelerates test-bench setup times for field engineers.

3. Factory Floor Industrial Automation and Cloud PLC Networking

For modern smart factories running extensive industrial IoT frameworks, localized machine CAN-FD communications must interface directly with enterprise Ethernet backbones. System integrators utilize the EID091-A601 or EID091-A601-S converters to aggregate 3 independent channels of CAN-FD networks into a unified TCP/UDP network stream. The built-in 120 ohms matching resistor can be software-activated via a host computer config tool, completely eliminating manual line-termination complexities on complex assembly lines.


FAQ Section

1. How does the microsecond-level latency of the ECAN-F02 benefit real-time automation systems?

The ECAN-F02 features specialized, ultra-fast internal processing logic that performs bidirectional conversion between electrical CAN(FD) signals and optical fiber waveforms within microseconds. This ensures that time-critical industrial payloads, such as motion control vectors or emergency alarm triggers, suffer no observable lag, providing deterministic real-time execution across distributed physical architectures.

2. What are the key configuration differences regarding bus termination between the EID091 Ethernet versions?

The EID091-A601 and EID091-A601-S models remove the physical hassle of manual jumper placements by integrating an internal 120 ohms terminal resistor directly onto the motherboard. System parameters can be adjusted directly via the host computer configuration software to enable or disable the resistor on demand, greatly streamlining long-term field troubleshooting and bus layout adjustment.

3. How do the conformal coatings protect these devices in harsh deployment sites?

All models, including the ECAN-F02 and the entire EID091 converter series, are factory-treated with a specialized industrial-grade conformal coating. This protective layer ensures the internal circuits achieve total compliance against humidity, mold growth, and salt spray oxidation, preventing unexpected electrical failure inside tropical marine environments, wastewater treatment plants, or damp outdoor enclosures.

Specifications

ECAN-F02, EID091-A101, EID091-A101-S, EID091-A601, EID091-A601-S

Disclaimer:This product is strictly prohibited for use in military applications and scenarios related to life safety. The user shall be fully liable for any unauthorized use.

domingo,lunes,martes,miércoles,jueves,viernes,sábado
enero,febrero,marzo,abril,mayo,junio,julio,agosto,septiembre,octubre,noviembre,diciembre
No hay suficientes ítems disponibles. Solo quedan [max].
Agregar a favoritosRevisar favoritosRemover favoritos
Bolsa de compras

Tu bolsa de compras está vacía.

Return To Shop

Agregar notas a la ordenEditar notas de la orden
Estimar envío
Agregar un cupón

Estimar envío

Agregar un cupón

Tu código de cupón se aplicará en el checkout

Ebyte EID091 Series ECAN-F02 Industrial CAN-FD to RS485 Ethernet Converter

ECAN-F02
ECAN-F02
$66.73