{"product_id":"jgd111-series-profinet-remote-io-module-16di-do-dual-rj45","title":"Ebyte JGD111 Series Profinet Remote IO Module 16DI\/DO Dual RJ45","description":"\u003cp\u003eThe Ebyte JGD111 series (JGD111-PDMP1616 \/ JGD111-PDR08) is an ultra-compact book-style PROFINET remote IO module providing 16DI+16DO transistor or 8DI+8DO relay channels, dual RJ45 switch ports, and 1ms real-time cycle over DC 9~36V power, featuring GSDML plug-and-play integration with Siemens S7-1200\/1500 PLCs and EMC Class 3 isolation for space-critical industrial automation.\u003c\/p\u003e\n\u003ch2\u003eKey Features \u0026amp; Advantages\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eNative PROFINET (RT) Real-Time Protocol \u0026amp; 1ms Cycle Time\u003c\/strong\u003e: Seamlessly integrates into standard PROFINET networks with deterministic I\/O refresh cycles up to 1ms, enabling direct high-speed memory mapping without custom communication programming.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInstant GSDML Engineering Integration\u003c\/strong\u003e: Provides official GSDML configuration files for one-click hardware catalog import into Siemens TIA Portal, STEP 7, PC Worx, and CODESYS, drastically shortening deployment and commissioning time.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFlexible High-Density I\/O Configurations (Transistor \/ Relay)\u003c\/strong\u003e: Choose between JGD111-PDMP1616 (16DI NPN\/PNP + 16DO Transistor\/MOSFET high-speed output) and JGD111-PDR08 (8DI NPN\/PNP + 8DO Relay dry-contact output) to match diverse field actuators and sensors.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSlim Book-Style Form Factor \u0026amp; Dual RJ45 Daisy-Chain Switch\u003c\/strong\u003e: Features a space-saving 30mm slim book-style DIN-rail enclosure with dual switched Ethernet ports, supporting cost-effective linear daisy-chain topologies without external industrial switches.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eCore Specifications\u003c\/h2\u003e\n\u003cdiv style=\"overflow-x: auto; margin: 20px 0;\"\u003e\n\u003ctable style=\"width: 100%; border-collapse: collapse; font-family: -apple-system, BlinkMacSystemFont, 'Segoe UI', Roboto, sans-serif; font-size: 14px; text-align: left; border: 1px solid #e0e0e0;\"\u003e\n\u003cthead\u003e\n\u003ctr style=\"background-color: #f7f9fa; border-bottom: 2px solid #d0d7de;\"\u003e\n\u003cth style=\"padding: 12px 16px; font-weight: 600; color: #24292f; border: 1px solid #e0e0e0; width: 35%;\"\u003eParameter\u003c\/th\u003e\n\u003cth style=\"padding: 12px 16px; font-weight: 600; color: #24292f; border: 1px solid #e0e0e0; width: 65%;\"\u003eSpecification \/ Value\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 10px 16px; font-weight: 500; color: #57606a; border: 1px solid #e0e0e0; background-color: #fafbfc;\"\u003eCommunication Protocol\u003c\/td\u003e\n\u003ctd style=\"padding: 10px 16px; color: #24292f; border: 1px solid #e0e0e0;\"\u003eStandard PROFINET (RT Class 1) Protocol\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 10px 16px; font-weight: 500; color: #57606a; border: 1px solid #e0e0e0; background-color: #fafbfc;\"\u003eEthernet Interface\u003c\/td\u003e\n\u003ctd style=\"padding: 10px 16px; color: #24292f; border: 1px solid #e0e0e0;\"\u003eDual RJ45 Ports (Integrated Switch, 100 Mbps Full Duplex, Auto MDI\/MDIX)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 10px 16px; font-weight: 500; color: #57606a; border: 1px solid #e0e0e0; background-color: #fafbfc;\"\u003eInternal Bus Cycle Time\u003c\/td\u003e\n\u003ctd style=\"padding: 10px 16px; color: #24292f; border: 1px solid #e0e0e0;\"\u003eUp to 1 ms Real-Time Cycle\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 10px 16px; font-weight: 500; color: #57606a; border: 1px solid #e0e0e0; background-color: #fafbfc;\"\u003eDigital Input (DI)\u003c\/td\u003e\n\u003ctd style=\"padding: 10px 16px; color: #24292f; border: 1px solid #e0e0e0;\"\u003eSupports NPN \/ PNP Dry and Wet Contacts, DC 10~28V Input Range, Optocoupler Isolated\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 10px 16px; font-weight: 500; color: #57606a; border: 1px solid #e0e0e0; background-color: #fafbfc;\"\u003eDI Sampling \u0026amp; Input Impedance\u003c\/td\u003e\n\u003ctd style=\"padding: 10px 16px; color: #24292f; border: 1px solid #e0e0e0;\"\u003e1000 Hz Sampling Frequency, 7.2 kOhm Input Impedance\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 10px 16px; font-weight: 500; color: #57606a; border: 1px solid #e0e0e0; background-color: #fafbfc;\"\u003eDigital Output (DO)\u003c\/td\u003e\n\u003ctd style=\"padding: 10px 16px; color: #24292f; border: 1px solid #e0e0e0;\"\u003ePDMP1616: 16-Ch Transistor (PNP\/MOSFET) | PDR08: 8-Ch Relay Output\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 10px 16px; font-weight: 500; color: #57606a; border: 1px solid #e0e0e0; background-color: #fafbfc;\"\u003eOperating Voltage \u0026amp; Power\u003c\/td\u003e\n\u003ctd style=\"padding: 10px 16px; color: #24292f; border: 1px solid #e0e0e0;\"\u003eDC 9 ~ 36V (Reverse Polarity Protection), Power Consumption: 2.0 ~ 4.0 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 10px 16px; font-weight: 500; color: #57606a; border: 1px solid #e0e0e0; background-color: #fafbfc;\"\u003eEMC \u0026amp; Electrical Isolation\u003c\/td\u003e\n\u003ctd style=\"padding: 10px 16px; color: #24292f; border: 1px solid #e0e0e0;\"\u003eEMC Class 3 Industrial Protection Standard, Full Optical Isolation between IO and Power\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 10px 16px; font-weight: 500; color: #57606a; border: 1px solid #e0e0e0; background-color: #fafbfc;\"\u003eForm Factor \u0026amp; Mounting\u003c\/td\u003e\n\u003ctd style=\"padding: 10px 16px; color: #24292f; border: 1px solid #e0e0e0;\"\u003eSlim Book-Style (120 * 30 * 80 mm), Standard 35mm DIN-Rail and Screw Mounting\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003ch2\u003eProduct Selection Guide\u003c\/h2\u003e\n\u003cdiv style=\"overflow-x: auto; margin: 20px 0;\"\u003e\n\u003cp style=\"font-size: 14px; font-weight: 600; color: #cf222e; margin-bottom: 10px;\"\u003e\u003cstrong\u003eNotice for Selection: Choose JGD111-PDMP1616 for high-speed high-density switching (16DI + 16DO Transistor output for solenoid valves, sensors, and indicators), or choose JGD111-PDR08 for high-current dry-contact switching (8DI + 8DO Relay output for intermediate contactors and AC\/DC loads).\u003c\/strong\u003e\u003c\/p\u003e\n\u003ctable style=\"width: 100%; border-collapse: collapse; font-family: -apple-system, BlinkMacSystemFont, 'Segoe UI', Roboto, sans-serif; font-size: 13px; text-align: center; border: 1px solid #e0e0e0;\"\u003e\n\u003cthead\u003e\n\u003ctr style=\"background-color: #f7f9fa; border-bottom: 2px solid #d0d7de;\"\u003e\n\u003cth style=\"padding: 12px 10px; font-weight: 600; color: #24292f; border: 1px solid #e0e0e0; text-align: left;\"\u003eModel SKU\u003c\/th\u003e\n\u003cth style=\"padding: 12px 10px; font-weight: 600; color: #24292f; border: 1px solid #e0e0e0;\"\u003eI\/O Specification\u003c\/th\u003e\n\u003cth style=\"padding: 12px 10px; font-weight: 600; color: #24292f; border: 1px solid #e0e0e0;\"\u003eDigital Input (DI)\u003c\/th\u003e\n\u003cth style=\"padding: 12px 10px; font-weight: 600; color: #24292f; border: 1px solid #e0e0e0;\"\u003eDigital Output (DO)\u003c\/th\u003e\n\u003cth style=\"padding: 12px 10px; font-weight: 600; color: #24292f; border: 1px solid #e0e0e0;\"\u003eNetwork Ports\u003c\/th\u003e\n\u003cth style=\"padding: 12px 10px; font-weight: 600; color: #24292f; border: 1px solid #e0e0e0;\"\u003eOperating Voltage\u003c\/th\u003e\n\u003cth style=\"padding: 12px 10px; font-weight: 600; color: #24292f; border: 1px solid #e0e0e0;\"\u003eDimensions \u0026amp; Weight\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 10px; font-weight: 600; color: #0969da; border: 1px solid #e0e0e0; text-align: left;\"\u003eJGD111-PDMP1616\u003c\/td\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid #e0e0e0;\"\u003e16DI + 16DO Transistor\u003c\/td\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid #e0e0e0;\"\u003e16 Channels (NPN\/PNP, 10-28V)\u003c\/td\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid #e0e0e0;\"\u003e16 Channels Transistor (MOSFET)\u003c\/td\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid #e0e0e0;\"\u003eDual RJ45 (Switch)\u003c\/td\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid #e0e0e0;\"\u003eDC 9 ~ 36V\u003c\/td\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid #e0e0e0;\"\u003e120 * 30 * 80 mm (140 +\/- 5 g)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #fafbfc;\"\u003e\n\u003ctd style=\"padding: 10px; font-weight: 600; color: #0969da; border: 1px solid #e0e0e0; text-align: left;\"\u003eJGD111-PDR08\u003c\/td\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid #e0e0e0;\"\u003e8DI + 8DO Relay\u003c\/td\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid #e0e0e0;\"\u003e8 Channels (NPN\/PNP, 10-28V)\u003c\/td\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid #e0e0e0;\"\u003e8 Channels Relay (Dry Contact)\u003c\/td\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid #e0e0e0;\"\u003eDual RJ45 (Switch)\u003c\/td\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid #e0e0e0;\"\u003eDC 9 ~ 36V\u003c\/td\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid #e0e0e0;\"\u003e120 * 30 * 80 mm (160 +\/- 5 g)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"ebyte-detail-images\" style=\"margin-bottom: 30px;\"\u003e\n\u003cp style=\"margin: 0; padding: 0; line-height: 0; text-align: center;\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0615\/5911\/1885\/files\/950_01_c9159ca5-2399-4d88-a0dd-4e6af4722b25.jpg?v=1793094699\" alt=\"Ebyte JGD111 Series PROFINET Remote IO Module Detail - 950_01.jpg\" style=\"width: 100%; max-width: 100%; display: block; margin: 0 auto;\"\u003e\u003c\/p\u003e\n\u003cp style=\"margin: 0; padding: 0; line-height: 0; text-align: center;\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0615\/5911\/1885\/files\/950_02_98b9d382-ea33-4e28-9f09-50574548f55f.jpg?v=1793094699\" alt=\"Ebyte JGD111 Series PROFINET Remote IO Module Detail - 950_02.jpg\" style=\"width: 100%; max-width: 100%; display: block; margin: 0 auto;\"\u003e\u003c\/p\u003e\n\u003cp style=\"margin: 0; padding: 0; line-height: 0; text-align: center;\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0615\/5911\/1885\/files\/950_03_7a33ac16-0967-4b43-9b80-ec17da380a42.jpg?v=1793094699\" alt=\"Ebyte JGD111 Series PROFINET Remote IO Module Detail - 950_03.jpg\" style=\"width: 100%; max-width: 100%; display: block; margin: 0 auto;\"\u003e\u003c\/p\u003e\n\u003cp style=\"margin: 0; padding: 0; line-height: 0; text-align: center;\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0615\/5911\/1885\/files\/950_04_319cff44-cc69-4edf-88cf-5db9699e3d75.jpg?v=1793094699\" alt=\"Ebyte JGD111 Series PROFINET Remote IO Module Detail - 950_04.jpg\" style=\"width: 100%; max-width: 100%; display: block; margin: 0 auto;\"\u003e\u003c\/p\u003e\n\u003cp style=\"margin: 0; padding: 0; line-height: 0; text-align: center;\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0615\/5911\/1885\/files\/950_05_1886b882-229b-4f82-b807-31a1310391eb.jpg?v=1793094699\" alt=\"Ebyte JGD111 Series PROFINET Remote IO Module Detail - 950_05.jpg\" style=\"width: 100%; max-width: 100%; display: block; margin: 0 auto;\"\u003e\u003c\/p\u003e\n\u003cp style=\"margin: 0; padding: 0; line-height: 0; text-align: center;\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0615\/5911\/1885\/files\/950_06_b927eede-a1fb-4002-8b10-ec24a3c726aa.jpg?v=1793094699\" alt=\"Ebyte JGD111 Series PROFINET Remote IO Module Detail - 950_06.jpg\" style=\"width: 100%; max-width: 100%; display: block; margin: 0 auto;\"\u003e\u003c\/p\u003e\n\u003cp style=\"margin: 0; padding: 0; line-height: 0; text-align: center;\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0615\/5911\/1885\/files\/950_07_cc587dc8-4707-4eb9-98b0-5d0117acd613.jpg?v=1793094699\" alt=\"Ebyte JGD111 Series PROFINET Remote IO Module Detail - 950_07.jpg\" style=\"width: 100%; max-width: 100%; display: block; margin: 0 auto;\"\u003e\u003c\/p\u003e\n\u003cp style=\"margin: 0; padding: 0; line-height: 0; text-align: center;\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0615\/5911\/1885\/files\/950_08_27ffe385-e082-466f-a9ee-2cd3881bbea1.jpg?v=1793094699\" alt=\"Ebyte JGD111 Series PROFINET Remote IO Module Detail - 950_08.jpg\" style=\"width: 100%; max-width: 100%; display: block; margin: 0 auto;\"\u003e\u003c\/p\u003e\n\u003cp style=\"margin: 0; padding: 0; line-height: 0; text-align: center;\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0615\/5911\/1885\/files\/950_09.jpg?v=1793094699\" alt=\"Ebyte JGD111 Series PROFINET Remote IO Module Detail - 950_09.jpg\" style=\"width: 100%; max-width: 100%; display: block; margin: 0 auto;\"\u003e\u003c\/p\u003e\n\u003cp style=\"margin: 0; padding: 0; line-height: 0; text-align: center;\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0615\/5911\/1885\/files\/950_10_94b66893-05cf-4a5d-a760-3c16fce5083e.jpg?v=1793094699\" alt=\"Ebyte JGD111 Series PROFINET Remote IO Module Detail - 950_10.jpg\" style=\"width: 100%; max-width: 100%; display: block; margin: 0 auto;\"\u003e\u003c\/p\u003e\n\u003cp style=\"margin: 0; padding: 0; line-height: 0; text-align: center;\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0615\/5911\/1885\/files\/950_11_79dcc291-7357-4fe7-8c80-495b47e349b0.jpg?v=1793094699\" alt=\"Ebyte JGD111 Series PROFINET Remote IO Module Detail - 950_11.jpg\" style=\"width: 100%; max-width: 100%; display: block; margin: 0 auto;\"\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003ch2\u003eIndustrial Installation \u0026amp; Wiring\u003c\/h2\u003e\n\u003cp\u003eThe JGD111 series features an ultra-slim 30mm book-style industrial ABS enclosure designed for standard 35mm DIN-rail mounting or direct screw panel mounting in space-constrained control cabinets. High-density spring-cage \/ screw pluggable terminal blocks allow fast, tool-free wiring. Dual RJ45 Ethernet ports support daisy-chain line connections from the master PLC through multiple JGD111 remote IO stations. Connect DC 9~36V main power to V+ and V- terminals. DI channels accept both sinking (NPN) and sourcing (PNP) sensor signals, while DO channels provide either solid-state transistor switching (PDMP1616) or isolated relay contact switching (PDR08).\u003c\/p\u003e\n\u003cp style=\"margin: 0; padding: 0; line-height: 0; text-align: center;\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0615\/5911\/1885\/files\/950_12_29202404-df2b-4516-b01d-44eadb387f1d.jpg?v=1793094699\" alt=\"Ebyte JGD111 Series Wiring \u0026amp; Terminal Definition - 950_12.jpg\" style=\"width: 100%; max-width: 100%; display: block; margin: 0 auto;\"\u003e\u003c\/p\u003e\n\u003cp style=\"margin: 0; padding: 0; line-height: 0; text-align: center;\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0615\/5911\/1885\/files\/950_13_ed4767c7-165d-4863-8107-c86bef117e72.jpg?v=1793094699\" alt=\"Ebyte JGD111 Series Wiring \u0026amp; Terminal Definition - 950_13.jpg\" style=\"width: 100%; max-width: 100%; display: block; margin: 0 auto;\"\u003e\u003c\/p\u003e\n\u003cp style=\"margin: 0; padding: 0; line-height: 0; text-align: center;\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0615\/5911\/1885\/files\/950_14_7786dd35-d2db-42ab-b51b-c06e87d1139e.jpg?v=1793094699\" alt=\"Ebyte JGD111 Series Wiring \u0026amp; Terminal Definition - 950_14.jpg\" style=\"width: 100%; max-width: 100%; display: block; margin: 0 auto;\"\u003e\u003c\/p\u003e\n\u003cp style=\"margin: 0; padding: 0; line-height: 0; text-align: center;\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0615\/5911\/1885\/files\/950_15.jpg?v=1793094699\" alt=\"Ebyte JGD111 Series Wiring \u0026amp; Terminal Definition - 950_15.jpg\" style=\"width: 100%; max-width: 100%; display: block; margin: 0 auto;\"\u003e\u003c\/p\u003e\n\u003cp style=\"margin: 0; padding: 0; line-height: 0; text-align: center;\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0615\/5911\/1885\/files\/950_16.jpg?v=1793094699\" alt=\"Ebyte JGD111 Series Wiring \u0026amp; Terminal Definition - 950_16.jpg\" style=\"width: 100%; max-width: 100%; display: block; margin: 0 auto;\"\u003e\u003c\/p\u003e\n\u003cdiv class=\"ebyte-text-specs\" style=\"margin-top: 30px;\"\u003e\n\u003ch2\u003ePractical Application Scenarios\u003c\/h2\u003e\n\u003ch3\u003e1. Automated Assembly Lines \u0026amp; Robotic Cell Distributed I\/O Extension\u003c\/h3\u003e\n\u003cp\u003eIn modern automotive assembly, electronics manufacturing, and packaging lines, distributed sensors and pneumatic valves are dispersed along long conveyor segments. Placing slim JGD111 book-style remote IO modules directly on field machine frames and daisy-chaining them via dual RJ45 ports saves extensive cabinet footprint and drastically cuts multiconductor cable installation costs back to the central Siemens S7-1500 PLC.\u003c\/p\u003e\n\u003ch3\u003e2. Logistics Warehousing Conveyors \u0026amp; High-Speed Sorting Systems\u003c\/h3\u003e\n\u003cp\u003eAutomated sorting systems and pallet conveyors require rapid response from photoelectric sensors, diverter gates, and proximity switches. With up to 1ms real-time PROFINET RT bus cycles and 1000Hz DI input sampling, the JGD111-PDMP1616 delivers deterministic, jitter-free signal acquisition to maintain exact package tracking and high-speed parcel routing.\u003c\/p\u003e\n\u003ch3\u003e3. CNC Machine Tool Tool-Changers \u0026amp; Pneumatic Actuation Panels\u003c\/h3\u003e\n\u003cp\u003eSpace inside machine tool electrical cabinets and auxiliary valve islands is strictly constrained. The compact 30mm width of the JGD111 module enables high-density installation alongside motor drives and safety relays. Its EMC Class 3 industrial noise immunity ensures immune operation against electromagnetic interference generated by adjacent VFDs and servo spindle motors.\u003c\/p\u003e\n\u003ch3\u003e4. HVAC Building Automation \u0026amp; Centralized Pumping Stations\u003c\/h3\u003e\n\u003cp\u003eBuilding management systems (BMS) and municipal water treatment plants require remote actuation of high-power contactors, motorized dampers, and alarm beacons. Utilizing the JGD111-PDR08 with 8 isolated relay outputs enables direct control of 250V AC loads without requiring additional external intermediate coupling relays, streamlining panel architecture.\u003c\/p\u003e\n\u003ch2\u003eFAQ Section\u003c\/h2\u003e\n\u003ch3\u003e1. How do I import the JGD111 module into Siemens TIA Portal or STEP 7?\u003c\/h3\u003e\n\u003cp\u003eDownload the official Ebyte GSDML XML file from the developer downloads section. In TIA Portal, navigate to Options \u0026gt; Manage General Station Description Files (GSD), select the GSDML file, and install it. The JGD111 module will appear under PROFINET IO \u0026gt; Field Devices \u0026gt; General \u0026gt; I\/O in your Hardware Catalog for drag-and-drop network integration.\u003c\/p\u003e\n\u003ch3\u003e2. Can the dual RJ45 ports be used as an internal Ethernet switch for daisy-chaining?\u003c\/h3\u003e\n\u003cp\u003eYes, the module integrates an onboard 2-port 100Mbps Ethernet switch. You can route an Ethernet cable from the PLC into Port 1, and extend an Ethernet cable from Port 2 to the next JGD111 module or PROFINET slave device in a linear daisy-chain line topology without needing an external industrial Ethernet switch.\u003c\/p\u003e\n\u003ch3\u003e3. How do I configure NPN vs PNP sensor inputs on the DI channels?\u003c\/h3\u003e\n\u003cp\u003eThe digital input circuit features bidirectional optocoupler isolation. Connecting the COM terminal to DC 24V enables NPN (sinking) sensor inputs, while connecting COM to DC 0V (GND) enables PNP (sourcing) sensor inputs, offering complete flexibility for international sensor wiring standards.\u003c\/p\u003e\n\u003ch3\u003e4. What is the difference between JGD111-PDMP1616 and JGD111-PDR08 output capabilities?\u003c\/h3\u003e\n\u003cp\u003eJGD111-PDMP1616 provides 16 transistor (MOSFET) solid-state outputs suitable for high-speed switching, PWM signaling, and electronic loads up to 500mA per channel. JGD111-PDR08 provides 8 relay dry-contact outputs capable of switching up to 250V AC \/ 30V DC loads, ideal for driving contactor coils and isolation circuits.\u003c\/p\u003e\n\u003c\/div\u003e","brand":"Ebyte Official Store - IoT Module Manufacturer","offers":[{"title":"JGD111-PDMP1616","offer_id":48846383317197,"sku":"JGD111-PDMP1616","price":71.51,"currency_code":"USD","in_stock":true},{"title":"JGD111-PDR08","offer_id":48846383349965,"sku":"JGD111-PDR08","price":57.91,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0615\/5911\/1885\/files\/01_a5420f9f-2de9-419b-8cdf-38affe1ca2dd.jpg?v=1793094714","url":"https:\/\/ebyteiot.com\/pt\/products\/jgd111-series-profinet-remote-io-module-16di-do-dual-rj45","provider":"Ebyte Official Store - IoT Module Manufacturer","version":"1.0","type":"link"}