Protocol Converter CAN to Ethernet Protocol Conversion Device – Ebyte Official Store - IoT Module Manufacturer

Ebyte ECAN Series High protection High-performance Protocol Converter CAN to Ethernet Protocol Conversion Device RS485/422/232

$25.24

Shipping calculated at checkout.

ECAN-E01S-V2 is a high-performance industrial Ethernet and CAN-bus data conversion device developed by Ebyte. It integrates 2 CAN-bus interfaces with a maximum baud rate of 1Mbps and 1 10M/100M Ethernet interface.... Read more

Availability: In Stock

Shipping: Free Air Shipping Over $89.99(China Post only)If the China post cannot deliver, other logistics need to pay extra postage delivery

Ship From: China EBYTE Manufacturer Factory

Bulk Purchase Tips: Please confirm the firmware version of the test sample with the salesperson before purchasing

Order today. Get it and , hoursminutes

Specification: ECAN-E01S-V2

  • ECAN-E01-V2
  • ECAN-E01S-V2
  • ECAN-E02
  • ECAN-S01
  • ECAN-101
  • ECAN-401
  • ECAN-401S
  • ECAN-W01
  • ECAN-W01S
  • ECAN-S01-TB
Will not ship until [19041994]
$25.24
Out of stock

Notify me when this product is available:

SKU: ECAN-E01S-V2N/A

Guaranteed Safe Checkout

paypalvisadiscovermaestroamerican express

When will the order be shipped?

We have sufficient goods in stock. We will send out goods within 1 to 2 working days after payment. We use China Post Air Mail as our regular shipping method. It normally takes 7 to 15 working days to arrive. Free shipping applies to orders over $89.99, excluding fiberglass antennas and power supplies. More Shipping Policies

How can I track my shipment?

After shipment, you will receive an email with the tracking number, such as LZ4177733XXCN. Check logistics status here: https://ebyteiot.com/apps/17TRACK

How to buy samples priced at $0.1?

You can mix different sample types. Each order can buy maximum 2 pieces. Buy $0.1 Sample

Where can I download product manuals?

You can download related documents directly on each product page. More materials:https://www.cdebyte.com/Product-Selection

How about product performance?

All EBYTE products support return and exchange within 30 days. Our items work steadily and you do not need to worry about after-sales problems.

What certifications do the products own?

Our goods have passed CE, FCC and RoHS certifications. You can download certification files on product pages directly, fully meeting compliance requirements.

What is the price for bulk purchase?

You can place bulk orders directly online. Large orders of 50, 200, 500, 1000 pieces and above enjoy factory discounted prices. Shipping cost can be checked on the page. Delivery takes 7 to 15 working days.

Why check firmware version before bulk order?

If you buy products in large quantity, please confirm the firmware version of bulk goods is the same as your test sample. This ensures normal operation of your project.
If you cannot confirm the version number, contact online customer service or send emails to ebyteiot@cdebyte.com for confirmation.

Can I apply for an invoice?

Send your request to ebyteiot@cdebyte.com and mark your order number like #3188, we will make the invoice for you quickly.

What if I bought the wrong product model?

  1. If your order has not been shipped, email us immediately to change the item or get a refund to place a new order.
  2. If your order has already been shipped, please contact us within 30 days to apply for return or refund. More Returns & Refunds Policies

What if the package is detained or sent back by customs?

We will refund you immediately after receiving the goods, or arrange redelivery twice.

How to solve other technical problems?

Contact online support staff or send emails to ebyteiot@cdebyte.com. Our professional engineers will help you fix all technical issues.

How to contact us?

Email: ebyteiot@cdebyte.com.

Phone: +86-028-61543675

Fax: 0086-028-64146160

ECAN-E01S-V2 is a high-performance industrial Ethernet and CAN-bus data conversion device developed by Ebyte. It integrates 2 CAN-bus interfaces with a maximum baud rate of 1Mbps and 1 10M/100M Ethernet interface. It supports TCP/UDP protocol and has a built-in 120 ohm resistor, which can be enabled by dialing. It supports working in the temperature range of -40℃ to 85℃. It has multiple working modes such as TCP Server, TCP Client, UDP, etc., and the parameters can be configured through the host computer configuration software. It can easily complete the intercommunication between CAN-bus network and Ethernet network.

Model Protocol Conversion Hardware Interfaces Supply Voltage Dimensions (mm) Key Features
ECAN-E01-V2 CAN to Ethernet 2× CAN, 1× RJ45 DC 8V~28V 82 × 84 TCP/UDP, 4 Working Modes
ECAN-E01S-V2 CAN to Ethernet 2× CAN, 1× RJ45 DC 8V~28V 100 × 84 × 25 TCP/UDP, Industrial Grade
ECAN-E02 CAN to Ethernet 1× CAN, 1× RJ45 DC 8V~28V 94 × 28 × 27 Compact Ethernet Bridge
ECAN-101 CAN to RS485 1× CAN, 1× RS485 DC 8V~28V Small Form Factor Modbus RTU, Transparent Trans.
ECAN-401 CAN to RS485/232/422 1× CAN, 1× Multi-Serial DC 8V~28V Standard Size 2500V DC Electrical Isolation
ECAN-401S CAN to RS485/232/422 1× CAN, 1× Multi-Serial DC 8V~28V 102 × 64 × 24 High-performance Bus Analyzer
ECAN-S01 CAN to TTL 1× CAN, 1× TTL DC 2.3V~5.5V 15 × 16 Ultra-small Smart Protocol Conv.
ECAN-S01-TB CAN to TTL Terminal Block Interface DC 2.3V~5.5V 50 × 23 Test Board for Easy Wiring
ECAN-W01 CAN to WiFi / Ethernet 2× CAN, 1× RJ45, WiFi DC 8V~28V 82 × 84 × 25 High-performance Wireless Gateway
ECAN-W01S CAN to WiFi / Ethernet 2× CAN, 1× RJ45, WiFi DC 8V~28V Standard Size Enhanced Industrial Protection

 

Download Datasheet

ECAN-E01-V2 Manual 
ECAN-E01S-V2 Manual
ECAN-E01-V2 Configuration Tool 
ECAN-E02 Manual 

ECAN-S01 Manual
ECAN-S01 Footprint
ECAN-S01 Pin definition 
ECAN-S01 Configuration tool 
ECAN-S01-TB Manual 

ECAN-101 Manual 
ECAN-101 Configuration tool 
ECAN-101 XCOM 

ECAN-401 Manual 
ECAN-401S Manual 
ECAN-401 Configuration tool 

ECAN-W01 Manual_EN_V1.0 
ECAN-W01S Manual_EN_V1.0 
ECAN-W01 Configuration tool 

Ebyte Company Profile 

 

2026415114469924

E101 Series

ECAN-E01-V2 CAN -Ethernet High-performance protocol converter Support CAN relay Integrated 10M/100M adaptive Ethernet chip Support four working modes

[Working voltage]:DC 8~28V

[Product size]: 82*84mm

[Product weight]: 120g

[Introduction]:ECAN-E01-V2 is a high-performance industrial Ethernet and CAN-bus data conversion device developed by Ebyte. The CAN gateway integrates 2 CAN-bus interfaces and 1 EtherNet interface, supports TCP/UDP protocol, and can easily complete the intercommunication between CAN-bus network and Ethernet network. The CAN gateway has a built-in 120 ohm resistor, which can be enabled by dialing; it supports working in the temperature range of -40℃~85℃. It has a 10M/100M Ethernet interface, high protection of CAN interface, and increased isolation; the maximum baud rate of 2 CAN ports is 1Mbps, with multiple working modes such as TCP Server, TCP Client, UDP, etc., and the parameters can be configured through the host computer configuration software.

Serial number project Specification
1 Supply voltage 8V~28VDC, more than 28V may burn out, 12V or 24V power supply is recommended
2 Network port specifications Standard RJ45, support 10/100Mbps
3 Network Protocol IP、 TCP/UDP、
4 Simple transparent transmission method TCP Server、TCP Client、UDP Server、UDP Client
5 TCP Server Connection Supports up to 14 TCP connections
6 How to obtain IP Static IP, DHCP
7 Domain name resolution support
8 User Configuration Host computer configuration
10 Operating temperature -40 ~ +85℃, industrial grade
11 Operating humidity 10% ~ 90%, relative humidity, non-condensing
12 Size See dimensional drawing
13 Average weight 120g
14 Storage temperature -40~+85℃, industrial grade

ECAN-E01S-V2 CAN -Ethernet High-performance protocol converter Support CAN relay Integrated 10M/100M adaptive Ethernet chip Support four working modes

[Working voltage]:DC 8~28V

[Network protocol]:IP, TCP/UDP

[Product size]:100*84*25mm

[Product weight]:120g

[Introduction]:

Serial number project Specification
1 Supply voltage 8V~28VDC, more than 28V may burn out, 12V or 24V power supply is recommended
2 Network port specifications Standard RJ45, support 10/100Mbps
3 Network Protocol IP、 TCP/UDP、
4 Simple transparent transmission method TCP Server、TCP Client、UDP Server、UDP Client
5 TCP Server Connection Supports up to 14 TCP connections
6 How to obtain IP Static IP, DHCP
7 Domain name resolution support
8 User Configuration Host computer configuration
10 Operating temperature -40 ~ +85℃, industrial grade
11 Operating humidity 10% ~ 90%, relative humidity, non-condensing
12 Size See dimensional drawing
13 Average weight 120g
14 Storage temperature -40~+85℃, industrial grade

 



Application

  • Industrial Factory Automation: By leveraging the integrated 10M/100M adaptive Ethernet chip, integrators can easily connect legacy CAN-bus PLCs to modern TCP/IP centralized SCADA networks. The multiple working modes (TCP Server/Client) ensure real-time machine monitoring with minimal packet delay.

  • Smart Grid & Power Monitoring: Substation environments often suffer from power fluctuations. The wide DC 8~28V supply voltage design guarantees continuous operation without resetting, securely converting diagnostic data from high-voltage switchgear into UDP streams for remote monitoring.

  • Automotive Manufacturing Diagnostics: Utilizing the maximum 1Mbps baud rate across 2 built-in CAN interfaces, engineers can simultaneously read and parse massive amounts of high-speed ECU data on the assembly line, preventing data bottlenecks during end-of-line vehicle testing.

  • Harsh Environment Mining Operations: Operating deep underground requires extreme hardware reliability. This module's industrial-grade temperature tolerance of -40℃ to 85℃ ensures that critical environmental sensor data is continuously relayed to the surface network without thermal-induced hardware failure.

FAQ

Q: How do I configure the internal termination for the CAN interface?

A: You can enable the built-in 120-ohm matching resistor by simply toggling the external dial switch. This eliminates signal reflection in high-speed or long-distance CAN bus topologies without the need to manually solder external resistors across CAN_H and CAN_L.

Q: What happens if the supply voltage fluctuates beyond the rated specifications?

A: The device operates safely within a DC 8V to 28V range. If the input voltage exceeds 28V, the internal power regulation circuitry and components may permanently burn out. It is highly recommended to use a regulated 12V or 24V industrial rail power supply to ensure stable logic levels.

Q: Can the network port automatically handle different types of Ethernet cables?

A: Yes, the integrated RJ45 port features a standard 10/100Mbps adaptive physical layer (PHY) that supports auto MDI/MDI-X. This means you can connect the module directly to a PC or to a network switch using either straight-through or crossover cables without encountering TX/RX mismatch issues.

Q: How does the device handle high bus loads during CAN to TCP conversion?

A: The onboard high-performance MCU is designed to process dual CAN channel inputs simultaneously at the maximum 1Mbps baud rate. It buffers the incoming CAN frames and packages them into TCP/UDP payloads efficiently, preventing frame dropping even during burst data transmission scenarios.

Specification

ECAN-E01-V2, ECAN-E01S-V2, ECAN-E02, ECAN-S01, ECAN-101, ECAN-401, ECAN-401S, ECAN-W01, ECAN-W01S, ECAN-S01-TB

Sunday,Monday,Tuesday,Wednesday,Thursday,Friday,Saturday
January,February,March,April,May,June,July,August,September,October,November,December
Not enough items available. Only [max] left.
Add to WishlistBrowse WishlistRemove Wishlist
Shopping cart

Your cart is empty.

Return To Shop

Add Order NoteEdit Order Note
Estimate Shipping
Add A Coupon

Estimate Shipping

Add A Coupon

10%OFF Code: ebyteiot ,Available for any order ,Coupon code will work on checkout page

Ebyte ECAN Series High protection High-performance Protocol Converter CAN to Ethernet Protocol Conversion Device RS485/422/232

ECAN-E01S-V2
ECAN-E01S-V2
$25.24