The Ebyte ME31-XDXX0400 is a PT100 thermal resistor temperature acquisition module with 4-channel PT100 temperature acquisition function, and supports the acquisition of 2/3-wire PT100 temperature sensors. Technical Parameter ME31-XDXX0400 Specification Remarks... Read more

Three Protections: The shell adopts three-proof coating, which is Anti-Fungal, Anti-Humidity, and Anti-Salt Spray.

Shipping: Free Air Shipping Over $89.99(China Post only)If the China post cannot deliver, other logistics need to pay extra postage delivery

Ship From: China EBYTE Manufacturer Factory

Bulk Purchase Tips: Please confirm the firmware version of the test sample with the salesperson before purchasing

Order today. Get it and , hoursminutes
Out of stock
SKU: ME31-XDXX0400N/ATags: IO, New product, RJ45, RS485

Guaranteed Safe Checkout

paypalvisadiscovermaestroamerican express

Every day, EBYTEIOT serves hundreds of clients worldwide, ensuring that we always remain responsive.

Free Shipping Terms:  

1、Free shipping for orders over $89.99 and under 1500g.

2、Orders over 1500g are not eligible for free shipping. Due to thin profit margins and high international courier costs. shipping fees shall be borne by customers.

3、Orders containing fiberglass antennas, magnetic base antennas or power supply modules are not eligible for free shipping (overweight, magnetic or battery-equipped goods).

 

Total time = processing time + shipping time (shipping time is business days)

Processing time = the time between placing an order and us shipping it.

Shipping time = the time it takes for your order to be shipped and delivered to you.

Processing time: 7 working days

Shipping time: 7-30 working days by China Post Air Mail.

We offer express delivery via DHL, FedEx, UPS and more. Extra shipping fees apply: https://ebyteiot.com/products/ebyte-dedicated-link-for-paying-postage

 

Important Reminder:

(Shipment may take several months at maximum due to uncontrollable factors including wars, geological disasters, bad weather and customs clearance.)

 

Please be advised that we do not deliver to

  • Cuba
  • Islamic Republic of Iran
  • Democratic People's Republic of Korea (North Korea).
  • Sudan
  • Syria
  • Venezuela
  • Yemen
  • Colombia
  • Israel

We apologize for any inconvenience this may cause.

 

Cancel order

We accept order cancellations before the product ships. If your order is cancelled, you will receive a full refund. If the product has already been shipped, the buyer can initiate a return or refund request within 30 calendar days of receiving the goods.


Returns

We accept product returns. Customers have the right to request a return within 30 days of receipt of the product. To be eligible for a return, your item must be unused and in the same condition you received it. It must also be in its original packaging. To complete your return, we require a receipt or proof of purchase.

If the return is caused by the consumer, the consumer will bear the shipping costs. The exact cost depends on the courier company you choose.

If the product is damaged or unusable due to our fault, such as product or transportation reasons, please contact EBYTE: ebyteiot@cdebyte.com. After communication with our technical staff, we will arrange for a reissue or refund.


Refund

Once your return has been received and inspected, we will send you a delivery notification via email. We will also notify you of approval or rejection of the refund. If you're approved, your refund will be processed and automatically credited to your credit card or original payment method within 15 business days.


Contact

Contact our customer service at ebyteiot@cdebyte.com.

Tel: +086 028 61543675

Return address: Building B5, No. 199, West District Avenue, High Tech West District Chengdu, China.

 

Auto-download documents via Ebyte official website link:

1、User Manual:https://www.cdebyte.com/pdf-down.aspx?id=3148
2、Configuration tool:https://www.cdebyte.com/pdf-down.aspx?id=3152
3、Ebyte Company Profile:https://www.cdebyte.com/pdf-down.aspx?id=1373

The Ebyte ME31-XDXX0400 is a PT100 thermal resistor temperature acquisition module with 4-channel PT100 temperature acquisition function, and supports the acquisition of 2/3-wire PT100 temperature sensors.

Technical Parameter ME31-XDXX0400 Specification Remarks / Details
Product Model ME31-XDXX0400 4-channel PT100 RTD Temperature Acquisition Module
Sensor Compatibility 4-channel 2-wire / 3-wire PT100 RTD High-accuracy RTD thermal resistor temperature sampling
Communication Interfaces RJ45 Ethernet Port and RS485 Serial Port Dual-port design supporting both local bus and network connectivity
Supported Protocols Modbus TCP and Modbus RTU Built-in Modbus Gateway with TCP/RTU protocol conversion
Local Display Screen Integrated OLED Display Screen On-site real-time temperature viewing and key configuration
Working Voltage DC 8V to 28V Wide supply input range suitable for industrial power supply
Installation Method 35mm DIN Rail Mounting / Screw Mounting Standard cabinet enclosure installation

 

Category  Name  Parameters
power supply Working voltage DC8~28V
Power indicator Blue LED indication
Communication Communication interface RJ45, RS485
Baud rate 1200~115200bps (default 9600)
Communication protocol Standard Modbus TCP, Modbus RTU protocol
MODBUS Device address Can be modified through Modbus command, host computer, device button
Temperature collection Number of channels 4-way
Sensor type 2, 3-wire PT100 temperature sensor
Temperature resolution 0.1℃
Accuracy Normal temperature (25±5℃) condition: ±0.1%±1℃
Full temperature (-40~85℃) condition: ±0.5%±1℃
Collection frequency 1Hz
Collection display OLED screen display
other Product size 121mm * 72mm * 34mm (length * width * height)
Product weight 140 ±5 g
Working temperature and humidity -40 ~ +85℃, 5% ~ 95%RH (no condensation)
Installation method Guide rail installation, screw installation


Category  Name  Parameters
Ethernet parameters Working mode TCP server (up to 4 client accesses)
Local IP 192.168.3.7
Local port 502
Subnet mask 255.255.255.0
Gateway address 192.168.3.1
DHCP Off
Local MAC Determined by the chip (fixed)
Target IP 192.168.3.3
Target port 502
DNS server 114.114.114.114
Active upload Off
Serial port parameters Baud rate 9600bps (8 types)
Check method None
Data bit 8
Stop bit 1
MODBUS Parameters Modbus master-slave Slave
Address 1

High precision and stability
Parameter Comparison Table
16 core functions
High-precision acquisition
High protection isolation
Real-time temperature display

Key Configuration

RS485 Cascade Expansion

Support 4-way socket link

ModBus Gateway Features

Remote I/O Series

Practical Application Scenarios

1. Multi-Zone Industrial Cold Storage and Pharmaceutical Temperature Telemetry

In cold chain logistics and pharmaceutical warehouses, strict multi-point temperature monitoring is required to prevent inventory spoilage. The ME31-XDXX0400 connects up to 4 high-precision 3-wire PT100 sensors across storage zones. Utilizing its RJ45 Ethernet port and Modbus TCP support, thermal data is continuously transmitted over LAN back to SCADA platforms. If local network maintenance occurs, field engineers can inspect channel temperatures directly on the front OLED display screen without hooking up external diagnostic laptops.

2. Modbus Protocol Gateway Conversion for Distributed Industrial PLC Automation

In legacy manufacturing plants upgrading to IoT architectures, centralized PLCs often need to poll serial slave devices over Ethernet. Operating as an intelligent Modbus gateway, the ME31-XDXX0400 automatically converts Modbus TCP queries from host controllers into Modbus RTU instructions sent via its RS485 port. System integrators combine the ME31-XDXX0400 with Ebyte serial servers and industrial switches to bridge legacy RS485 slave meters into enterprise Ethernet networks, streamlining hardware deployment and saving panel space.

3. Remote Substation Transformer and Cabinet Thermal Monitoring

Power distribution cabinets and electrical transformers require continuous thermal tracking to detect overheating risks before equipment failure occurs. Mounted on standard 35mm DIN rails, the ME31-XDXX0400 acquires 4-channel PT100 thermal resistor readings directly from busbars and transformer cores. By interconnecting its RS485 port with an Ebyte 4G DTU cellular modem, the module transmits real-time Modbus RTU telemetry to remote cloud control centers for automated over-temperature alerting across widely dispersed grid substations.


FAQ Section

1. How does the integrated Modbus Gateway functionality in the ME31-XDXX0400 simplify industrial network expansion?

The ME31-XDXX0400 features hardware protocol routing that converts between Modbus TCP over Ethernet and Modbus RTU over RS485. When non-local Modbus addresses are detected, the module automatically routes commands between its serial and network ports. This eliminates the need for standalone protocol converters when adding new RS485 slave IO devices to an existing Ethernet SCADA architecture.

2. What wiring advantages does supporting both 2-wire and 3-wire PT100 sensors offer?

The module supports both 2-wire and 3-wire PT100 thermal resistors across its 4 acquisition channels. Utilizing 3-wire PT100 sensors enables automatic lead wire resistance compensation, which eliminates measurement errors caused by long cable runs in large-scale industrial facilities. 2-wire compatibility provides flexible, low-cost deployment options for short-distance thermal monitoring.

3. What on-site debugging features are provided by the onboard display screen?

The ME31-XDXX0400 includes an integrated OLED display screen paired with front configuration keys. Field technicians can view real-time temperature telemetry for all 4 PT100 channels, verify network IP settings, and adjust Modbus slave addresses on-site without needing dedicated software, computer cables, or handheld serial debuggers.


Disclaimer:This product is strictly prohibited for use in military applications and scenarios related to life safety. The user shall be fully liable for any unauthorized use.

Sunday,Monday,Tuesday,Wednesday,Thursday,Friday,Saturday
January,February,March,April,May,June,July,August,September,October,November,December
Not enough items available. Only [max] left.
Add to WishlistBrowse WishlistRemove Wishlist
Shopping cart

Your cart is empty.

Return To Shop

Add Order NoteEdit Order Note
Estimate Shipping
Add A Coupon

Estimate Shipping

Add A Coupon

10%OFF Code: ebyteiot ,Available for any order ,Coupon code will work on checkout page

EBYTE ME31-XDXX0400 Temperature Acquisition Module 4-way PT100 RTD Ethernet RS485 With OLED Display Screen Support Modbus

$30.50