EBYTE ME31-AAAX2240 ModBus Ethernet I/O Network Acquisition Control Module RS485 Rail Installation 2DI+2AI+4DO Industrial Grade - IOT Module Shop Manufacturer Factory – Ebyte Official Store - IoT Module Manufacturer

EBYTE ME31-AAAX2240 ModBus Ethernet I/O Network Acquisition Control Module RS485 Rail Installation 2DI+2AI+4DO Industrial Grade

$28.99

Shipping calculated at checkout.

ME31-AAAX2240 is equipped with 4 Type A relay outputs and 2analog (0-20mA/4-20mA) inputs, 2 dry contact input detection, supports Modbus TCP protocol or Modbus RTU protocol for acquisition and control,and the equipment is... Read more

Three Protections: The shell adopts three-proof coating, which is Anti-Fungal, Anti-Humidity, and Anti-Salt Spray.

Shipping: Free Air Shipping Over $89.99(China Post only)If the China post cannot deliver, other logistics need to pay extra postage delivery

Ship From: China EBYTE Manufacturer Factory

Bulk Purchase Tips: Please confirm the firmware version of the test sample with the salesperson before purchasing

Order today. Get it and , hoursminutes
Out of stock
SKU: ME31-AAAX2240N/ATags: 2DI+2AI+4DO, RS485

Guaranteed Safe Checkout

paypalvisadiscovermaestroamerican express

Every day, EBYTEIOT serves hundreds of clients worldwide, ensuring that we always remain responsive.

Free Shipping Terms:  

1、Free shipping for orders over $89.99 and under 1500g.

2、Orders over 1500g are not eligible for free shipping. Due to thin profit margins and high international courier costs. shipping fees shall be borne by customers.

3、Orders containing fiberglass antennas, magnetic base antennas or power supply modules are not eligible for free shipping (overweight, magnetic or battery-equipped goods).

 

Total time = processing time + shipping time (shipping time is business days)

Processing time = the time between placing an order and us shipping it.

Shipping time = the time it takes for your order to be shipped and delivered to you.

Processing time: 7 working days

Shipping time: 7-30 working days by China Post Air Mail.

We offer express delivery via DHL, FedEx, UPS and more. Extra shipping fees apply: https://ebyteiot.com/products/ebyte-dedicated-link-for-paying-postage

 

Important Reminder:

(Shipment may take several months at maximum due to uncontrollable factors including wars, geological disasters, bad weather and customs clearance.)

 

Please be advised that we do not deliver to

  • Cuba
  • Islamic Republic of Iran
  • Democratic People's Republic of Korea (North Korea).
  • Sudan
  • Syria
  • Venezuela
  • Yemen
  • Colombia
  • Israel

We apologize for any inconvenience this may cause.

 

Cancel order

We accept order cancellations before the product ships. If your order is cancelled, you will receive a full refund. If the product has already been shipped, the buyer can initiate a return or refund request within 30 calendar days of receiving the goods.


Returns

We accept product returns. Customers have the right to request a return within 30 days of receipt of the product. To be eligible for a return, your item must be unused and in the same condition you received it. It must also be in its original packaging. To complete your return, we require a receipt or proof of purchase.

If the return is caused by the consumer, the consumer will bear the shipping costs. The exact cost depends on the courier company you choose.

If the product is damaged or unusable due to our fault, such as product or transportation reasons, please contact EBYTE: ebyteiot@cdebyte.com. After communication with our technical staff, we will arrange for a reissue or refund.


Refund

Once your return has been received and inspected, we will send you a delivery notification via email. We will also notify you of approval or rejection of the refund. If you're approved, your refund will be processed and automatically credited to your credit card or original payment method within 15 business days.


Contact

Contact our customer service at ebyteiot@cdebyte.com.

Tel: +086 028 61543675

Return address: Building B5, No. 199, West District Avenue, High Tech West District Chengdu, China.

 

Auto-download documents via Ebyte official website link:

ME31-AAAX2240 is equipped with 4 Type A relay outputs and 2analog (0-20mA/4-20mA) inputs, 2 dry contact input detection, supports Modbus TCP protocol or Modbus RTU protocol for acquisition and control,and the equipment is also A network I/O networking module that can be used as a simple Modbus gateway (automatically send commands with non-local Modbus addresses through the serial port/network port).

[Specifications]:2DI+2AI+4DO

[DI channels]:2-way

[AI channels]:2-way

[DO channels]:4-way

[Installation method]:DIN-Rail Mounting

[Size]:121*72*34mm

[Product weight]:150 ±5 g

 

Name Parameter
Operating voltage DC 8~28V
Power indicator Blue LED indication
Communication Interface RJ45, RS485
Baud rate 9600bps (customizable)
Protocol Modbus TCP, Modbus RTU
Device address TModify via Modbus command and computer
DI channels 2
Input type Default dry node
Acquisition frequency 1 kHz
Input indicator LED display
AI channels 2
Acquisition characteristics Single-ended input
Input type 0-20mA, 4-20mA
AI resolution 1‰
Acquisition frequency 10Hz
Input instructions LED display
DO channel 4
DO output type Type A Relay
DO output mode Level output, pulse output
Relay contact capacity 30V/7A、250V/7A
Output indication Red LED
Product Size 121mm * 72mm * 34mm (Length*width*height)
product weight 150 ± 5 g
Working temperature and humidity -40 ~ +85℃、5% ~ 95%RH(No condensation)
Storage temperature and humidity -40 ~ +105℃、5% ~ 95%RH(No condensation)
Installation method DIN rail installation



Ethernet+R5485 Dual control

16 Core Functions Worry-free protocol, easy adaptation

High-precision analog acquisition Real-time data display

Button Configuration with Virtual Serial Port Software

Digital Input Photoelectric Isolation

With Host Computer Software Configurable Input Range

DI Filter Anti-jitter Pulse Count

Input And Output Linkage Function Active Reporting Of Status

Support 4-way Socket Link DNS Domain Name Resolution

ModBus Gateway Function

Product Size Digital input

Remote I/O Series

 

Practical Application Scenarios

1. Industrial Pump Station Automation

In water supply or sewage pumping stations, this module monitors liquid level sensors (via AI channels) and float switches (via DI channels). If levels become critical, the controller triggers the relay outputs (DO channels) to activate pumps or emergency alarms, ensuring full automated closed-loop management without manual intervention.

2. Remote Energy Consumption Management

The ME31-AAAX2240 integrates with industrial smart meters to monitor analog current loads. By utilizing its gateway functionality, it transmits data to a central SCADA system. Maintenance teams can remotely toggle heavy electrical equipment via the relay outputs to manage peak loads and ensure facility safety from a central control room.

3. Distributed Environmental Monitoring

For smart factories, this module collects data from environmental sensors (like CO2 or humidity transmitters outputting 4-20mA signals). It enables local control of ventilation fans and exhaust systems through its relay outputs, allowing for an autonomous environmental response system that adapts in real-time to factory floor conditions.


FAQ Section

1. What does it mean for the module to act as a "simple Modbus gateway"?

This device can automatically forward Modbus commands from a master controller to secondary slave devices connected to its serial port. This allows your central system to communicate with multiple downstream slave devices through this single module, effectively extending your existing network infrastructure without needing additional hubs.

2. Are the digital inputs compatible with common industrial sensors?

Yes, the 2 dry contact inputs are designed for standard industrial switches, push-buttons, and relay status signals. They provide a high level of isolation and stability, making them compatible with almost all standard binary output sensors used in factory automation.

3. How do I switch between 0-20mA and 4-20mA modes for analog inputs?

The module supports these input ranges through software configuration. By modifying the Modbus registers, users can select the desired analog range to match their specific sensors, ensuring accurate conversion and data acquisition across different industrial instrumentation.

Disclaimer:This product is strictly prohibited for use in military applications and scenarios related to life safety. The user shall be fully liable for any unauthorized use.

Sunday,Monday,Tuesday,Wednesday,Thursday,Friday,Saturday
January,February,March,April,May,June,July,August,September,October,November,December
Not enough items available. Only [max] left.
Add to WishlistBrowse WishlistRemove Wishlist
Shopping cart

Your cart is empty.

Return To Shop

Add Order NoteEdit Order Note
Estimate Shipping
Add A Coupon

Estimate Shipping

Add A Coupon

10%OFF Code: ebyteiot ,Available for any order ,Coupon code will work on checkout page

EBYTE ME31-AAAX2240 ModBus Ethernet I/O Network Acquisition Control Module RS485 Rail Installation 2DI+2AI+4DO Industrial Grade

$28.99