EBYTE MA01-AXCX4020 ModBus RTU Serial IO Module RS485 Interface 4DI+2DO 8 Digital Outputs Rail Installation 8~28VDC - IOT Module Shop Manufacturer Factory – Ebyte Official Store - IoT Module Manufacturer

EBYTE MA01-AXCX4020 ModBus RTU Serial IO Module RS485 Interface 4DI+2DO 8 Digital Outputs Rail Installation 8~28VDC

$10.99

Shipping calculated at checkout.

The Ebyte MA01-AXCX4020 supports the acquisition of 4-channel sensor switch input (DI), which is converted to serial port (RS485) and data is transmitted to configuration software or PLC. The serial port I/O networking... Read more

Shipping: Free Air Shipping Over $89.99(China Post only)If the China post cannot deliver, other logistics need to pay extra postage delivery

Ship From: China EBYTE Manufacturer Factory

Bulk Purchase Tips: Please confirm the firmware version of the test sample with the salesperson before purchasing

Order today. Get it and , hoursminutes
Sin existencias

Ebyteiot provides invoices. Bulk order discounts. 24/7 tech support, product selection & project solutions. Manuals and certifications available for download.

SKU: MA01-AXCX4020No disponibleEtiquetas: 4DI + 2DO, RS485

Guaranteed Safe Checkout

paypalvisamasteramerican expressdiscoverjcbdiners clubpix

When will the order be shipped?

We have sufficient goods in stock. We will send out goods within 1 to 2 working days after payment. We use China Post Air Mail as our regular shipping method. It normally takes 7 to 15 working days to arrive. Free shipping applies to orders over $89.99, excluding fiberglass antennas and power supplies. More Shipping Policies

How can I track my shipment?

After shipment, you will receive an email with the tracking number, such as LZ4177733XXCN. Check logistics status here: https://www.17track.net/en

How to buy samples priced at $0.1?

You can mix different sample types. Each order can buy maximum 2 pieces. Buy $0.1 Sample

Where can I download product manuals?

You can download related documents directly on each product page. More materials:https://www.cdebyte.com/Product-Selection

How about product performance?

All EBYTE products support return and exchange within 30 days. Our items work steadily and you do not need to worry about after-sales problems.

What certifications do the products own?

Our goods have passed CE, FCC and RoHS certifications. You can download certification files on product pages directly, fully meeting compliance requirements.

What is the price for bulk purchase?

You can place bulk orders directly online. Large orders of 50, 200, 500, 1000 pieces and above enjoy factory discounted prices. Shipping cost can be checked on the page. Delivery takes 7 to 15 working days.

Why check firmware version before bulk order?

If you buy products in large quantity, please confirm the firmware version of bulk goods is the same as your test sample. This ensures normal operation of your project.
If you cannot confirm the version number, contact online customer service or send emails to ebyteiot@cdebyte.com for confirmation.

Can I apply for an invoice?

Send your request to ebyteiot@cdebyte.com and mark your order number like #3188, we will make the invoice for you quickly.

What if I bought the wrong product model?

  1. If your order has not been shipped, email us immediately to change the item or get a refund to place a new order.
  2. If your order has already been shipped, please contact us within 30 days to apply for return or refund. More Returns & Refunds Policies

What if the package is detained or sent back by customs?

We will refund you immediately after receiving the goods, or arrange redelivery twice.

How to solve other technical problems?

Contact online support staff or send emails to ebyteiot@cdebyte.com. Our professional engineers will help you fix all technical issues.

How to contact us?

Email: ebyteiot@cdebyte.com.

Phone: +86-028-61543675

Fax: 0086-028-64146160

Auto-download documents via Ebyte official website link:

The Ebyte MA01-AXCX4020 supports the acquisition of 4-channel sensor switch input (DI), which is converted to serial port (RS485) and data is transmitted to configuration software or PLC. The serial port I/O networking module (also known as "remote IO") that controls 2 relay switch outputs (DO) by issuing commands through the serial port to realize remote acquisition and control functions.

[Specifications]:4DI + 2DO

[Interface mode]:RS485

[Installation method]:positioning hole

[Product weight]:80±5g

[Size]:50*80mm

 

Manual Download

manual
configuration tool
Company Proflile

 


parameter name value

Operating Voltage

8~28V (DC)
Communication interface RS232/RS485
Protocol Modbus RTU
baud rate 1200~115200 bps(default 9600 bps)
data bit 8
stop bit 1
Check Digit None
Digital input (DI) stem node
Analog input (AI) -
Acquisition frequency 100 Hz
trigger method Pulse trigger / level trigger
Digital output (DO) Relay output
Contact capacity (DO) 10A/30 VDC 、   10A/250 VAC
Power indicator (Power) Green LED indication
Input indication (DI) Green LED indication
Input Indication (AI) Green LED indication
Output indication (DO) Red LED indication
Working temperature, humidity -40℃ ~ +85℃ 、5%~95%RH 、no condensation
storage temperature, humidity -60℃ ~ +125℃ 、5%~95%RH 、no condensation
installation method Rail installation or positioning hole installation

I/O network modules with serial port

Using guide rail installation

Practical Application Scenarios

1. Production Line Equipment Status Monitoring with NB144 Serial Server

Connect MA01-AXCX4020 DI ports to proximity switches and emergency stop buttons on automated assembly lines, upload equipment running signals via RS485 bus to Ebyte NB144 4-channel serial server. The module’s 100Hz fast sampling captures transient fault signals instantly, relay DO channels control line alarm lights and solenoid valves for interlock protection. Optoelectronic isolation eliminates motor EMI interference in high-power production workshops, and Modbus RTU data is forwarded to remote factory SCADA platforms over Ethernet.

2. Smart Greenhouse Irrigation Automatic Control System

Match this remote IO module with Ebyte EID041 temperature humidity transmitters; DI channels read soil moisture dry contact sensor signals, DO ports drive water pump and ventilation fan contactors. Wide DC8-28V voltage adapts off-grid solar power supply for field greenhouses, dual rail & wall mounting fits compact control boxes, and anti-surge hardware protects circuits from outdoor lightning surge interference.

3. Building Access Control & Exhaust Fan Linkage Management

Deploy MA01-AXCX4020 inside weak current cabinets of office buildings: DI collects door magnetic switch and card reader trigger signals, DO automatically starts workshop exhaust fans when access control is activated. Dry contact DI design matches mainstream access control hardware, standard Modbus protocol connects to building PLC, and industrial wide temperature range works stably in unheated basement equipment rooms.

4. Photovoltaic Junction Box Fault Signal Collection

Install multiple MA01-AXCX4020 units at distributed PV combiner boxes, DI channels collect circuit breaker on-off status signals of each string, relay DO outputs trigger site warning beepers for abnormal power generation. RS485 bus long-distance transmission reduces wiring costs across large solar farms, three-proof shell coating resists dust and salt fog in open-air photovoltaic stations.

5. Warehouse Conveyor Safety Interlock Control

Link DI ports to safety grating and limit position sensors on logistics conveyor belts, DO channels control conveyor motor contactors to cut power when safety signals trigger. Pulse trigger mode captures fast belt movement signals without data loss, EMC multi-layer protection avoids signal distortion from frequency converter electromagnetic noise, and compact size saves cabinet installation space.

 

FAQ Section

1. Can MA01-AXCX4020 be directly connected to 5V or 24V dry contact sensors without extra conversion boards?

Yes, its DI channels adopt universal dry contact input design, compatible with all passive proximity switches, door magnetic sensors and limit switches with no voltage requirement. No level shifting or signal conversion hardware is needed between the module and common industrial dry contact devices.

2. What is the maximum number of MA01-AXCX4020 modules that can be connected on one single RS485 bus?

The Modbus address range supports 1 to 255 unique station IDs, theoretically up to 247 modules can be mounted on one RS485 bus under reasonable load. Engineers should reduce baud rate when connecting more than 30 units to prevent bus data congestion and packet loss.

3. Can the relay DO channels drive high-power AC contactors directly?

The relay contacts support maximum 10A 250VAC load for small loads like indicator lights and miniature valves. For large AC contactors with current over 5A, users need to add intermediate relay amplifiers to avoid contact burnout from overcurrent.

4. Does the optoelectronic isolation block ground loop noise in long-distance RS485 wiring?

Input opto-isolation and independent DC-DC isolated power separate field sensor circuits and main control bus circuits completely, cutting off ground loop current generated by long cable potential difference, which effectively eliminates common mode interference and random signal jump faults.

5. Is the graphical configuration software provided free for MA01-AXCX4020 parameter modification?

Ebyte provides free official Windows graphical configuration tool without activation fees, supporting one-click modification of Modbus address, baud rate, DI filter parameters and DO output logic; the software can be downloaded from the official product documentation page.

Disclaimer:This product is strictly prohibited for use in military applications and scenarios related to life safety. The user shall be fully liable for any unauthorized use.

domingo,lunes,martes,miércoles,jueves,viernes,sábado
enero,febrero,marzo,abril,mayo,junio,julio,agosto,septiembre,octubre,noviembre,diciembre
No hay suficientes ítems disponibles. Solo quedan [max].
Agregar a favoritosRevisar favoritosRemover favoritos
Bolsa de compras

Tu bolsa de compras está vacía.

Return To Shop

Agregar notas a la ordenEditar notas de la orden
Estimar envío
Agregar un cupón

Estimar envío

Agregar un cupón

Tu código de cupón se aplicará en el checkout

EBYTE MA01-AXCX4020 ModBus RTU Serial IO Module RS485 Interface 4DI+2DO 8 Digital Outputs Rail Installation 8~28VDC

$10.99