PN1-D25P Single-port Profinet to ModBus gateway Support Siemens PLC networking RS485/422 compatible with RS485 Easy configuration [Communication interface]:RS485+RS422+RJ45 [Working voltage]: DC 8~28V [Installation method]:Guide rail installation [Product size]:55*30*80mm [Product weight]:130±5g [Introduction]:PN1-D25 is... Read more

Three Protections: The shell adopts three-proof coating, which is Anti-Fungal, Anti-Humidity, and Anti-Salt Spray.

Shipping: Free Air Shipping Over $89.99(China Post only)If the China post cannot deliver, other logistics need to pay extra postage delivery

Ship From: China EBYTE Manufacturer Factory

Bulk Purchase Tips: Please confirm the firmware version of the test sample with the salesperson before purchasing

Order today. Get it and , hoursminutes
Out of stock
SKU: PN1-D25PN/A

Guaranteed Safe Checkout

paypalvisadiscovermaestroamerican express

Every day, EBYTEIOT serves hundreds of clients worldwide, ensuring that we always remain responsive.

Free Shipping: All product orders with a total amount exceeding $89.99 qualify for free shipping.

Total time = processing time + shipping time (shipping time is business days)

Processing time = the time between placing an order and us shipping it.

Shipping time = the time it takes for your order to be shipped and delivered to you.

Processing time: 7 working days


Shipping time: 7-15 working days by China Post Air Mail (may take up to 45 working days due to unpredictable factors such as weather and customs processing).

 

Please be advised that we do not deliver to

  • Cuba
  • Islamic Republic of Iran
  • Democratic People's Republic of Korea (North Korea).
  • Sudan
  • Syria
  • Venezuela
  • Yemen

We apologize for any inconvenience this may cause.

 

Cancel order

We accept order cancellations before the product is shipped. If your order is canceled, you will receive a full refund. We cannot intercept order cancellations if the product has already been shipped.


Returns

We accept product returns. Customers have the right to request a return within 30 days of receipt of the product. To be eligible for a return, your item must be unused and in the same condition you received it. It must also be in its original packaging. To complete your return, we require a receipt or proof of purchase.

If the return is caused by the consumer, the consumer will bear the shipping costs. The exact cost depends on the courier company you choose.

If the product is damaged or unusable due to our fault, such as product or transportation reasons, please contact EBYTE: ebyteiot@cdebyte.com. After communication with our technical staff, we will arrange for a reissue or refund.


Refund

Once your return has been received and inspected, we will send you a delivery notification via email. We will also notify you of approval or rejection of the refund. If you're approved, your refund will be processed and automatically credited to your credit card or original payment method within 15 business days.

Contact

Contact our customer service at ebyteiot@cdebyte.com.

Tel: +086 028 61543675

Return address: Building B5, No. 199, West District Avenue, High Tech West District Chengdu, China.

 

EBYTE product technical manual and detailed parameters download: https://www.cdebyte.com/Product-Selection


PN1-D25P Single-port Profinet to ModBus gateway Support Siemens PLC networking RS485/422 compatible with RS485 Easy configuration

[Communication interface]:RS485+RS422+RJ45

[Working voltage]: DC 8~28V

[Installation method]:Guide rail installation

[Product size]:55*30*80mm

[Product weight]:130±5g

[Introduction]:PN1-D25 is a Profinet to Modbus RTU gateway used to map Modbus data to Profinet.The shell adopts three-proof coating, which is Anti-Fungal, Anti-Humidity, and Anti-Salt Spray.
Use GSD files for integration, code-free reading and writing of Modbus devices, and quickly set up data and transfer it to the PLC. The gateway provides 1 RS485 and 1 RS422 (compatible with RS485) interfaces, each supporting 32 command nodes, for a total of 64 command nodes. All Modbus commands are loaded in module form, and the memory mapping relationship between Profinet and Modbus is intuitive and can be queried in STEP 7 or TIA Portal software. The status byte can be loaded to query the connection status of the Modbus device and monitor the device status in real time.

category name parameter
power supply Operating voltage DC 8~28V; with reverse connection protection
Power indicator PWR red LED indicator
Network port parameters Interface Type RJ45
Communication Protocol Standard Profinet protocol (RT)
Maximum communication cycle 4ms
Communication bandwidth 10/100M adaptive
RS485 serial port parameters Interface Type RS485 (5.08mm terminal block)
Communication Protocol Standard Modbus RTU protocol
Baud rate 1200~3.9M bps
Communication Format Data bits: 7/8 Bits (default 8)
Stop bits: 1/2 Bits (default 1)
Check: None/Odd/Even (default None)
RS422 serial port parameters Interface Type RS422 (5.08mm terminal block)
Communication Protocol Standard Modbus RTU protocol
Baud rate 1200~3.9M bps
Communication Format Data bits: 7/8 Bits (default 8)
Stop bits: 1/2 Bits (default 1)
Check: None/Odd/Even (default None)
Work Environment Working temperature and humidity -40 ~ +85℃, 5% ~ 95%RH (no condensation)
Storage temperature and humidity -40 ~ +105℃, 5% ~ 95%RH (no condensation)
other Product size 55mm * 30mm * 80mm (length * width * height)
Product Weight 115 ± 5 g (single Ethernet port); 130 ± 5 g (dual Ethernet ports)
Installation Standard industrial grade 35mm rail installation

ProfiNet to ModBus gateway

12 core functions

Parameter comparison table

Support ProfiNet to ModBus protocol

TIA Portal/STEP 7 configuration

Directly provide GSD

Support Siemens full range

Provide two serial ports

Independent serial port channels

Cascade expansion

Stable without downtime

Modbus master and slave

High-speed data transmission

High protection level

Easy to install
Stable and Reliable Performance
Industrial-grade quality more stable and reliable

Application topology diagram

Dimensional drawing

Parameter specification

Application scenarios

Sunday,Monday,Tuesday,Wednesday,Thursday,Friday,Saturday
January,February,March,April,May,June,July,August,September,October,November,December
Not enough items available. Only [max] left.
Add to WishlistBrowse WishlistRemove Wishlist
Shopping cart

Your cart is empty.

Return To Shop

Add Order NoteEdit Order Note
Estimate Shipping
Add A Coupon

Estimate Shipping

Add A Coupon

10%OFF Code: ebyteiot ,Available for any order ,Coupon code will work on checkout page

Ebyte PN1-D25P EU CE certification Applicable to Siemens PLC RS485+RS422+RJ45 Single-port ProfiNet to ModBus Gateway RTU

$50.53