| Spec Category | Parameter Dimension | Technical Specifications (Ebyte E54-24LD12A) |
| Core Hardware | Technology Type | 24GHz Millimeter-Wave Radar (FMCW/CW) |
| Antenna Array | 1T1R (1 Transmit, 1 Receive) | |
| RF Performance | Operating Frequency | 24 GHz (Standard 24GHz ISM Band) |
| Transmitting Power | 12 dBm | |
| Physical Specs | Form Factor Size | 20 mm x 20 mm |
| Product Weight | 1.2 grams (plus or minus 0.2 grams) | |
| Functionality | Detection Targets | Moving, micro-moving, and stationary human bodies |
| Software Support | Dedicated Visual Configuration Tool for parameter tuning | |
| Deployment Mode | Plug-and-play embedded integration |
| Parameter | Minimum value | Typical values | Maximum value | unit | Remark |
| Specifications | |||||
| Support frequency bands | twenty four | - | 24.25 | GHz | Comply with FCC, CE, and committee-free certification standards |
| Supports maximum scanning bandwidth | - | 0.25 | - | GHz | |
| Maximum equivalent omnidirectional radiated power | - | 12 | - | dBm | - |
| Power supply voltage | 3 | 3.3 | 3.6 | In | - |
| size | - | 20 * 20 | - | mm | ±0.2mm |
| Ambient temperature | -40 | - | 85 | ℃ | - |
| System Performance | |||||
| Detection range (wall hanging) | - | 10 | - | m | Exercise human goals |
| - | 6 | - | m | Exercise human goals | |
| Detection range (top) | - | 5 | - | m | Exercise human goals |
| - | 4 | - | m | Exercise human goals | |
| Detection accuracy | - | 0.15 | - | m | Moving target within 10m of straight line distance from the sensor |
| Average operating current | - | 50 | - | and | - |
| Data refresh cycle | - | 100 | - | ms | - |
| weight | - | 1.2 | - | g | ±0.2g |